10 Maintenance and repair
WARNING
High electrical voltage!
Risk of serious injury and even death from electrical shock.
Disconnect the relevant system component before you perform maintenance and
repair work.
Secure the system against unintentional restarting.
High pneumatic pressure!
Risk of serious injury and even death.
Disconnect the relevant system component from the pneumatic pressure source
before you perform maintenance and repair work.
All pneumatic cylinders must be depressurized (vented).
Secure the system against unintentional restarting.
CAUTION
Hot surfaces of the electric motors in operation!
Burns can result from the > 65 °C surfaces.
Provide for appropriate guard devices.
Let the unit cool down at least 30 minutes before performing maintenance and/
or repair work.
• Continuous conveyors which are in motion or in operation may only be inspected
and adjusted once all required safeguards are in place.
• Note EN ISO 13857 when you remove or replace safeguards and/or nullify a safety
guideline.
• Test runs with open panels are only allowed if they are carried out by a competent
person using tip switches and no interference through other switching elements
exists.
10.1 Cleaning and care
NOTICE
Failure of the bearings
Applying grease-dissolving substances to the bearing points, e.g. when cleaning,
leads to the failure of the bearings. There is a risk of damage to property, and the
service life may be reduced.
Keep degreasers or aggressive cleaning away from the bearings!
Clean the product only with a damp cloth.
Failure of the toothed belt
Applying grease-dissolving substances to the toothed belt, e.g. when cleaning, leads
to the failure of the toothed belt. There is a risk of damage to property.
Keep degreasers or aggressive cleaning away from the toothed belt
Clean the product only with a damp cloth.