8.8“ Touchscreen Colour Display AHD 880 TC
Errors
V5
59
In Case of Error
As a rule:
1.
Determine the cause of the error.
2.
Immediately inform a responsible party on-site.
3.
Depending on the error type, have an authorized specialist
correct it, or correct it on your own.
4.
Correct the error by replacing or repairing the defective parts
(e.g. cables, plugs, etc.).
5.
If the error cannot be determined through the error table, a
device defect cannot be excluded. For repairs, send the de-
vice to the manufacturer’s address or to an authorized spe-
cialist company.
9.2
Power / Fault LED
The LEDs on the device front provide information about the condi-
tion of the Color Display AHD 880 TC.
The Power LED is lit continuously as soon as the device is con-
nected to the supply power. When it extinguishes, the supply volt-
age is either too low, or it is interrupted.
The Fault LED can indicate the conditions “OFF,” “ON,” or “BLINK-
ING.” If no error condition is determined, the Fault LED is not lit. If
the fault LED is blinking, the CAN data communication is inter-
rupted, and the device receives no data from the other ship alarm
system components connected to the network. The blinking com-
mences after a 5 second delay.
If the Fault LED is continuously lit after booting during the startup
process, the device does not have a valid configuration. In this
case, the manufacturer or an authorized representative must be
contacted.
Continuous ON
Continuous OFF
BLINKING
Power LED
Device operational
Device has not supply
power
-
Fault LED
Device not configured
correctly. Contact
manufacturer.
Device functions error-free.
Interruption of CAN data