25
To adjust the compressor settings for a channel:
1
On the appliance Web UI’s main page, select
DSP
.
2
Select the
Menu
button for the channel.
3
From the drop-down menu, select
Compressor
.
4
Make desired adjustments using the controls described in
.
5
Select
Enable
to apply the settings to the selected channel.
Note:
If you want to return to the factory settings, select the
Reset
icon that appears in
the right corner.
Table 9. Compressor Settings
Enable
Enables or disables the compressor DSP effect for this
channel.
Threshold
Sets the threshold level, which is the point where the
signal activates the compressor circuit.
The range is -135 to +21 dB.
Attack
Sets how quickly or slowly compression will be applied
to the signal once the audio signal goes above the
threshold level. It specifies the length of time over which
the compression ratio will gradually increase from no
compression to full compression.
The range is 1 to 500 ms.
Hold
Sets how long compression will be applied after the sig
-
nal has fallen below the threshold.
The range is 1 to 500 ms.
Decay
Sets how quickly or slowly compression will be removed
from the signal after the signal has dropped below the
threshold
and
the Hold interval has expired. It specifies
the length of time over which the compression ratio will
gradually decrease from full compression to no com
-
pression.
The range is 0 to 2000 ms.