34
PHENIX Green US
Version 12-40
5.2. C
ertifiCations
& p
erformanCes
The PHENIX Green 75, 85, 95 and 120 are certified according to norm EN
13229:2001 and EN 13229 A2:2004 (Inset appliance fired by solid fuel) that
measure their performances as the following:
Recommended fuel: well seasoned dry firewood
Phenix75
Phenix85
Phenix95
Phenix120
Input
7.1 lb/h
8.3 lb/h
8.8 lb/h
11.2 lb/h
Output
37543 Btu’s 41638 Btu’s 45734 Btu’s
58942 Btu’s
Efficiency
82%
77.3%
76%
76%
CO in com-
bustion pro-
duct
0.096%
0.091%
0.097%
0.096%
Flue gas tem-
perature
206.4°C/
403°F
236°C/
457°F
252°C/
486°F
266°C/
511°F
This appliance has also been tested and approved by Guardian Fire Testing
Labs, Inc. based on the following standards:
UL 127 and ULC S-610-M93
EPA Wood Burning Fireplace Program Qualified
5.2. C
ertifiCations
et
p
erformanCes
Les PHENIX Green 75, 85, 95 et 120 sont certifiés selon la norme EN13229:2001
et l’EN 13229 A2:2004 (Inset appliance fired by solid fuel). Les performances
évaluées sont les suivantes:
Combustible recommandé: bois de chauffe bien sec
Phenix75
Phenix85
Phenix95
Phenix120
Input
3.21 kg/h
3.75 kg/h
4 kg/h
5.07 kg/h
Output
37543 Btu’s 41638 Btu’s 45734 Btu’s
58942 Btu’s
Rendement
82%
77.3%
76%
76%
CO in com-
bustion pro-
duct
0.096%
0.091%
0.097%
0.096%
Température
des fumées à
la sortie
206.4°C/
403°F
236°C/
457°F
252°C/
486°F
266°C/
511°F
Cet appareil a également été testé par Guardian Fire Testing Labs, Inc. selon
les normes suivantes:
UL 127 et ULC S-610-M93
Qualification Program Foyer Bois EPA
Summary of Contents for PHENIX Green