FAULT PROTECTION
Electronic Load Fuse Protection
Each load output is protected by an internal electronic fuse. Electronic fuses are
auto-recoverable and eliminate the need for the user to replace a blown fuse.
The electronic fuse will act if the BatteryPlus35-II detects a current greater than the
current rating of the terminal. The Load Output Status Indicator will be flashing red
and the System Status Indicator will be solid red.
The BatteryPlus35-II will automatically reconnect a faulty output up to 3 times within
a 45-second window. If the fault is still present after the 3rd attempt, the output will
be permanently disabled. Normal operation may resume once the fault has been
rectified and the system is reset.
The system can be reset by pressing the reset button, or by disconnecting all sources
(AC mains, auxiliary, solar and battery).
Note
: Activating the remote switch (RSW) has the same e
ff
ect as disconnecting the
battery.
Over-Temperature, Over-Voltage and Short Circuit Overload Protection
The BatteryPlus35-II provides automatic protection for over-temperature, over-
voltage and short circuit overload situations.
If any of these situations are detected, the BatteryPlus35-II will shut down and
automatically attempt a restart every 30 seconds until the fault is removed.