INSTALLATION INSTRUCTIONS
EARTHING
As the BatteryPlus35-II is positive sensing for current monitoring, this allows for
chassis earthing of both the battery and the negative of DC 12V appliances.
Note:
All DC 12V positive cables must be wired to outputs 1-14 or the 40A battery
output connection.
Loads greater than 15A
For DC 12V appliances that may draw greater than 15A, such as inverters, both
positive and negative must be wired directly to the new battery negative on the
BC300 to ensure the current is seen by the BatteryPlus35-II and the correct
information displayed, such as the State of Charge and Time Remaining.
Refer to our website for more information on this product:
products/bc300-commlink-external-shunt/
PERSONNEL
Installation is to be carried out only by suitably qualified personnel.
13
More information https://www.caravansplus.com.au