5. AUX+
Connection point for external DC input positive.
6. BATT+
Connection point for battery positive terminal. Attach fuse to Batt+ wiring.
7. BATT-
Connection point for battery negative terminal.
8. NOT USED
9. RESET (MASTER RESET BUTTON)
Press the Master Reset Button if any part of the system is unresponsive or not
operating correctly during or after installation
10. CAN BUS COMMUNICATION CONNECTOR
To connect to and power BMPRO accessories (BC300 + CommLink External Shunt
or OdysseyLink) or monitors (RVView or Trek).
11. REMOTE SWITCH TERMINAL BLOCK (RSW)
Terminal block for connecting an optional remote switch. This switch is used to
disconnect the loads from all power.
Terminals are labelled according to their designated load output
Table 3: Designated terminal-load outputs
TERMINAL OUTPUTS
LOAD RATING
1
Tablet / Spare
15A
2
Spare
15A
3-9
Spare
10A
10
Light 1
10A
11
Light 2
10A
12
Light 3
10A
13
Pump 1
10A
14
Pump 2
10A