14. SOLAR PANEL CONNECTION
Connection used for solar panel input.
15. +BRK BATTERY OUTPUT (40A MATCH RATED)
16. SYSTEM STATUS INDICATOR
Indicates the operational status of the BatteryPlus35-II.
12. MOUNTING HOLE (X4)
13. LOAD OUTPUT STATUS INDICATORS
LED COLOUR
LOAD OPERATIONAL STATUS
GREEN
Loads operating normally
FLASHING RED
Fault with load
OFF
Load is o
ff
Table 4: LED Status Indicators
This output is an uncontrolled 15th output with a maximum current rating of 40A.
This is specifically designed for loads which do not need to be isolated or have a
current rating higher than the inbuilt circuit protection of the individual outputs
and have a current rating less than 40A. This may include, but not be limited to:
9
BMPRO SwayControl
9
BMPRO Trailsafe (+)
9
Heaters
9
Stereo memory
WARNING
Loads connected to +BRK output will not turn o
ff
even during ECO mode or Storage mode.
To maintain good health of the battery during low voltage, manually turn these loads o
ff
.
Exceeding 40A total load current may turn o
ff
some of the load outputs 1-14. All loads
connected on this output must be individually fused.
WARNING
If braking systems are already connected to the +BRK output, non-braking loads must use
a separate output.
12
More information https://www.caravansplus.com.au