Wire Size
DC cables must be sized to carry the maximum full load current and to not exceed the
system volt drop requirements. The following cable sizes are recommended. When
running wires, if they pass through panels or wall, ensure the wires are protected
from damage by sharp edges. The use of cable glands is recommended.
Table 5: Wire Size Recommendations
CURRENT
MINIMUM WIRE SIZE
0-10A
1.0mm
2
or 18 AWG
10-20A
3.0mm
2
or 14 AWG
20-30A
5.5 mm
2
or 10 AWG
LOAD, BATTERY AND EXTERNAL DC INPUT CONNECTIONS
Up to 14 loads may be connected. Loads are attached using female spade Quick
Connects (QC). See
Figure 4: Quick Connect Dimensions
.
All load negative returns must be connected directly to the BatteryPlus35-II negative
terminals only.
Figure 3:
Quick Connect Dimensions
6.8mm
The wiring method used with the installation shall be in accordance with National
Electrical Code ANSI/NFPA 70.
18
More information https://www.caravansplus.com.au