For greater work pressure when cleaning shallow containers, the
number of nozzles can be reduced from four to three in the top
outermost side array, using the bung provided as standard (2).
Important: there must be no fewer than three nozzles per array. The
working pressure must not exceed 100 bars.
Clean the drain filter in the tank regularly.
6.7 Noise
Lp dB(A) 91 (uncertainly 1,5) - Lw dB(A) 96
Reference Standard EN60335-2-79
6.8 Vibrations
The vibrations produced are minimal and do not represent a source
of danger for the operator.
No particular procedures must be adopted in order to
safeguard the operator from the effects of the vibrations
produced. In the event of abnormal vibrations, the operator
should immediately stop the machine and contact maintenance
personnel.
6.9 Degree of protection of the machines (IP)
Degree of protection against solid objects (protected
against dust)
5
Degree of protection against water (protected against
splashes of water)
4
6.10 Admissible environmental values
Admissible environmental values
Admissible operating
temperatures
-10°C - 50°C
(50° F - 113° F)
Relative humidity range
75% or less
Vibrations
≤
0.5 G
The machine is not suitable for operating in environments at risk
from fire or explosion.
7 Routine maintenance
IMPORTANT - During routine maintenance, cleaning
and extraordinary maintenance, personal protection
devices provided must be worn.
IMPORTANT - Failure to observe the following safety
rules may cause injury, death or damage to
equipment.
IMPORTANT - All maintenance and cleaning must be
performed with the machine off and the key taken out.
In the case of the internal combustion engine model,
the plug cable must be detached and the motor cold
to avoid burns and fire. Do not allow personnel not
involved in maintenance to approach the machine
7.1 Safety rules for routine maintenance
Routine maintenance involves a series of simple operations to be
performed at regular intervals and according to the manufacturer's
instructions. The Manufacturer has reduced the number and
complexity of routine maintenance operations to enable them to be
performed by personnel without technical expertise or complex
equipment. It involves above all:
Check the level of oil in the pump by means of the
indicator light on the pump itself.
Clean the connectors and grease the connector gaskets
IMPORTANT - When replacing oil, it must be disposed
of in respect of current legislation. Under no
circumstances may it be disposed of in the
environment.
7.2 Safety regulations for cleaning the machine
All cleaning operations must be performed with the machine
stationary and turned off.
When cleaning the machine or its components, the following
precautions must be observed:
Do not clean electrical equipment with water or other fluids. To
remove dust, use a clean brush or dry cloth only. Do not clean
plastic surfaces with alcohol, detergent or solvents. Dispose of
cleaning materials in respect of current legislation. Do not
dispose of the materials used or cleaning residues in the
environment. To clean, use water or compressed air and soft
cloths. IMPORTANT - During cleaning, personnel protection
devices must be worn
7.3 Safety regulations for repairs and extraordinary
maintenance
For all operations over and above normal routine maintenance,
contact an authorised repair workshop.
All operations must be performed by qualified
personnel with the necessary technical skills to
perform the operations in the maximum safety and in
respect of current legislation.
It should be noted that the warranty offered by the manufacturer is
invalidated if:
The instructions given in the "use and maintenance"
manual are not scrupulously respected,
Routine maintenance is not performed as and when
indicated;
Lubricants other than those specified are used;