12
DuraSweeper
®
Suggested Concrete Pad Specification - Permanent Model Standard Layout
Concrete pads should be at a minimum 6 inch depth and have a minimum compressive strength of
3,000 lb. Wedge anchors require a minimum embedment depth of 3.375 inches. The minimum pad foot
prints are shown in the Standard Concrete Layout and Non-Standard Concrete Layout. Edge of bollard
base plate should be recessed from all pad edges by at least 6".
Note: Concrete piers can be used in place of concrete pads. Contact Bluff for additional information.
Vehicle Travel
PERMANENT MODEL
Standard Concrete Layout
this drawing is for
Suggested Concrete Pad Specification - Permanent Standard Layout
model for this drawing: DS-PermanentStandardConcrete
25 ft
7 ft
24 ft
3 ft
11 ft
13 ft
12 ft
Bluff Bollard
SRB42
Bluff Bollard
SRB42
Bluff Bollard
SRB42
Bluff Bollard
SRB42
Bluff Bollard
SRB42
Bluff Bollard
SRB42