D.6.4 A
CTIVATING THE
IPMI O
PTION
The Serial Access Unit (KV9-SRL) contains the necessary software to use IPMI with
the ServSwitch.
You can use either serial port on the ServSwitch to send IPMI access; your choice
will dictate the cable type you will use to make the connection. The DTE serial port
on the front panel requires a null-modem serial cable.
Connect a serial cable’s female end to the serial port that’s configured for IPMI
access on the host computer. Connect the opposite end to the ServSwitch unit’s
DTE serial port.
D.6.5 C
ONFIGURING
IPMI
ON THE
S
ERV
S
WITCH
Once you have connected the IPMI-configured serial port to the ServSwitch and
enabled the software option, you can begin to configure IPMI settings through the
Web interface.
Log into the Web interface as
admin
. Choose
Serial Ports
from the Admin menu
on the Home screen in the Web interface, then select
IPMI/IPMB setup
(Intelligent Platform Management)
.
The screen shown in Figure D-1 appears.
Figure D-1. IPMI Status screen.
Make the following changes to enable IPMI:
• Enable IPMI (Intelligent Platform Management Interface) via the serial port:
select
Enabled
from the drop-down menu in Figure D-1.
• From the drop-down menu in Figure D-1, select which serial port to use: select
Front serial port (DTE pinout)
since the ServSwitch has DTE serial port only.