7.6 Restore Factory Defaults
The device can be reset to its original factory default settings using a control sequence
through the serial interface or by using a DIP-switch. Depending on the operating mode, the
macro memory may also be reset.
Use DIP- switch 6 to reset the device. In the “Cross point Switch” operating mode, all macros
in memory are reset.
Standard operating mode
Reset
the ACX4000- Switch to default settings (Factory Reset):
1.
switch power off
2.
set the DIP switch
3.
switch power on, the device is resetting
4.
switch power off
5.
set the DIP switch back
6.
switch power on - done
Using the serial interface, execute this command to reset the device:
•
STX, 0x45, ETX
Reset to factory settings
In the “Cross point Switch” operating mode, all macros in memory are reset.