40
start searching for all Slaves, as shown below.
=
=
F
L
.
. .
L
L
If wiring is correct, this screen will appear:
L
=
=
:
L
L
F
After receiving the control command from the Master, all Slaves will be locked
on the SLAVE screen and all keys except
are disabled so that slaves
cannot be operated by pressing front keys. This ensures the Master supply be
in control.
:
:
Once the Master and Slave settings are done, users can then operate the Master
only to set up the output voltage and current.
To release from this operation mode (series operation mode in this example),
press
(LCL) to access to the series/parallel setting screen and turn
the knob to select OFF for series/parallel selection to leave the series or
parallel operation mode and return to the local operation mode so that the
power supply can be controlled by pressing the front keys again. Do not
change the operation mode while the instruments are in their output state or
they will cause the Master’s communication to fail and display an error
message. After power-off, if you want to keep the previous series/parallel
setting, please turn on the Slave first. Then turn on the Master.