24
Note:
If you are not sure of the IP settings, consult
your network administrator.
2. OUTPUT SETTING:
Press
in the first page of the menu to enter OUTPUT SETTING
menu.
VOLT LIMIT MAX:
Upper limit of the output voltage setting
XLN15010 –
150.5 V max.
XLN30052 –
300.5 V max.
XLN60026 –
600.5 V max.
CURR LIMIT MAX:
Upper limit of the output current setting
XLN15010 –
10.45 A max.
XLN30052 –
5.25 A max.
XLN60026 –
2.65 A max.
VOLT LIMIT MIN:
Lower limit of the output voltage setting.
5 V min. for all models.
CURR LIMIT MIN:
Lower limit of the output current setting
XLN15010 –
0.04 A min.
XLN30052 –
0.02 A min.
XLN60026 –
0.01 A min.
VOLT SLEW RATE:
Voltage ascending/descending slope
VOLT LIMIT MAX = _300.50 V
CURR LIMIT MAX = 4.5000 A
VOLT LIMIT MIN = 0.000 V
CURR LIMIT MIN = 0.010 A
VOLT SLEW RATE = 3.300 V/mS
CURR SLEW RATE = 0.0520 A/mS