88
4.7.2
Output Control Commands
This set of commands controls the outputs of the selected instrument
(based on their address). Use
CADR
command (described in previous
section) first to select the address of the unit you want to control before
using any of these commands to control that unit’s output.
Command
Description
==================================================
CPV
Sets the output voltage value in Volts
CPV?
Reads the output voltage setting
CMV?
Reads the actual output voltage
CPC
Sets the output current value in Amperes
CPC?
Reads the output current setting
CMC
Reads the actual output current
CDVC?
Display voltage and current data
COUT
Turns the output to ON or OFF
COUT?
Returns the output On/Off status
COV
Sets the OVP level
COV?
Returns the OVP setting level
COVP
Sets the OVP on/off
COVP?
Returns the OVP on/off
COC
Sets the OCP level
COC?
Returns the OCP setting level
COCP
Sets the OCP on/off
COCP?
Returns the OCP on/off
COP
Sets the OPP level
COP?
Returns the OPP setting level
COPP
Sets the OPP on/off
COPP?
Returns the OPP on/off
CMODE?
Returns the power supply operation mode
==================================================
Summary of Contents for XLN10014
Page 90: ......
Page 94: ...Model XLN15010 XLN30052 XLN60026 High Power Programmable DC Power Supply USER MANUAL...
Page 113: ...17 voltage is within the specified range...
Page 204: ...108...
Page 206: ...110...