75
6.7
LAN Communication (-GL versions)
XLN series power supplies provide three LAN control modes, including Web
server, Telnet and Sockets. First, enter the first Item “System Setting” on the
menu to set the interface selection (Remote Control) to Ethernet. Then, select
IP setting procedure as Static. An IP address is required to complete setup.
After completed, the supply will be able to use the above LAN control mode to
control the power supply.
Using Web Server
XLN series with the –GL option have a built-in Web Server. User can
control the power supply on a computer using a Web browser. Open
Web browser and input IP address to enter the Welcome page, as
shown below.
Enter password (default is 123456) to login the main page (Home), and
then click the links on the left column to configure or control settings.