Camera Control Registers
CON41 Register
Version G.5
BitFlow, Inc.
NEO-8-111
AFE_PORT_
DATA
R/W, CON41[7..0], Alta
Used to access the AFE. The value written in this bitfield will be use written to the AFE
during the next write operation. For read operations, the value read from the AFE will
be available in this bitfield after the read operation is complete.
AFE_PORT_
BUSY
RO, CON41[8], Alta
Used when accessing the AFE.
AFE_PORT_
ERROR
RO, CON41[9], Alta
A 1 in this bit indicates that an error occurred during the last AFE access operation.
AFE_PORT_
RESET
WO, CON41[10], Alta
Writing a 1 to the bit resets the AFE access mechanism.
AFE_PORT_BUSY
Meaning
0
The AFE access operation is completed.
1
The AFE access operation is still taking place, the
data address/data ports can not be read/written.
Summary of Contents for NEO-PCE-CLB
Page 8: ... TOC 6 BitFlow Inc Version ...
Page 22: ...Virtual vs Hardware Frame Grabbers The Neon NEO 1 12 BitFlow Inc Version G 5 ...
Page 64: ...NTG Control Registers The Neon NEO 3 6 BitFlow Inc Version G 5 ...
Page 90: ...PoCL Control Registers The Neon NEO 6 6 BitFlow Inc Version G 5 ...
Page 266: ...Power Consumption The Neon NEO 12 6 BitFlow Inc Version G 5 ...
Page 294: ...NEO PCE DIF I O Connector Pinout P3 The Neon NEO 13 28 BitFlow Inc Version G 5 ...
Page 300: ...Index BitFlow Inc ...