INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Pellet burner Bisolid GP xx R tsc OM-BSGPRTSCV00/11/2016/EN
23
5.11.1 COMMON SETTINGS
Table 8. Parameters of pellet burner common settings
5.11.2 IGNITION SETTINGS
Name
Designation
Limmits
Factory setting
Water limmits
Tb lim
5 – 90 °C
15 – 80 °C
Zone regulation
Zone reg
5 – 30 °C
10 °C
Type of control mode
Type control
0 – manual
1 – room thermostat
1
Choise of flame sensor
Flame sensor
0 – photo
1 – flue gases
0
Recovery from the loss of
power
Lose AC Restore
0 – “Stop”
1 – “Burn”
0
Delayed of the reaction of
the flow sensor
FC delay
1 – 240 s
30
Pulse/revolutions
Fan1 pulse/rev
0 – 12
0 – inactive
0
Common Settings
*Tb lim
15 – 80 °C
Zone reg
10 °C
Type control
0
Flame sensor
0
Common Settings
*Lose AC Restore
0
FC_delay
5
Fan1 pulse/rev
12
EXIT
Ignition
*Load
60 s
Blowing
2m
Fire time
8 m
Preheat
160 s
Ignition
*Fan1
48 %
Fan 2
100 %
Inflame
120 s
Delay
5 s
EXIT
Ignition
*Tubus work
0 %
EXIT