The user has to periodically, at least once per day or longer, depending on the fuel ash
content, but no longer than five days of operation, to switch off the burner. This measure
guarantees effective after-burning of the fuel and combustion chamber cooling.
After the pellet burner cools down the ash and/or slag must be cleaned from the combustion
chamber fire-grate. The flexible pipe connecting the fuel transport auger and the burner fuel
inlet pipe must be cleaned from dust at least once per week.
Dust depositing on the flexible pipe walls can lead to distortion of the fuel
feeding, ignting the dust as a result of emergency situation, in consequence of
which hot flue gasses might pass through it.
It is necessary that the user is fully introduced with the information presented in
the current operation manual, in connection with the pellet burner operation, its