INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Pellet burner Bisolid GP xx R tsc OM-BSGPRTSCV00/11/2016/EN
19
Figure 7. Front control panel of tube pellet burner series Bisolid GP xx R tsc
1. Front panel indication – intuitive LCD display.
2. Changing button “Forward” / or manually switching on/off the pellets transport
auger (if holded for 5 sec. together with additionally known conditions described
below).
3. Changing button “Back”.
4. Button for Enter/Exit from programming mode (user settings), switch ON/OFF (if
holded for 5 sec).
5. Button ON/OFF.
Figure 8. Displey indication of pellet burmer series Bisolid GP xx R tsc
1
2
3
4
5
6
7
8
9
10
11
12
13
↑
↓
Напред
Назад
Промяна
ON/OFF
ignition
In the basic state the display shows the following parameters:
1. Time and day of the week.
2. Execution of weekly program N ....
3. Stop / Start / Burn - performed procedure.
4. Current exploited power.
5. Indicator cleaner work / entry into cleaning.
6. Indicator ignitor operation, room thermostat or alarm .
7. Indicator work auger nimbers 1 and 2 blinks in manual switching.
8. Indicator working fans with nimbers 1 and 2.
9. Indicator working pump.
10. Tfg - temperature flue gas (assignment).
12. Fire - light sensor (assignment).
13. Tb - water temperature.
3
4
5
1
2
Forward
Back
Enter/Exit
ON/OFF