5.12. SMS COMMANDS
GSM module is offered as an option, it connects to "CON7" the board with indication. When
the module is available, display shows the symbol for GSM. SMS commands must be in Latin
characters, as assuming only large or only small letters.
Example: BSTOP and bstop – correct, Bstop – wrong.
Table 13. Description of GSM commands for pellet burner control
BSTOP and BSTART commands have the same effect as a button ON/OFF, as in switch on
condition is executed the set weekly program.
In an emergency, if no recorded number is checked for the last sent SMS and if it is missing
and he is not sent alert.
During the receiving of SMS command is returning SMS response to the number from which
the command is recieved.
5.13. CONNECTING THE PELLET BURNER TO THE ELECTRICAL
POWER SUPPLY
When connecting the rotary tube pellet burner series Bisolid GP xx R tsc to the electrical
power supply installation it is necessary to have in mind the following technical characteristics
(Table 14).
Name
Designation
Action
Stop pellet burner
BSTOP
Burner stops – the same like with button ON / OFF
Start pellet burner
BSTART
Burner starts – the same like with button ON / OFF
Current condition
BINFO
Send SMS with the current condition
Telephone in an
emergency
BPHONE
Recorded phone from which the message is sent if
there is no flame, no air flow or the blocking
thermostat is activated and sends alert