INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Pellet burner Bisolid GP xx R tsc OM-BSGPRTSCV00/11/2016/EN
24
Table 9. Parameters in pellet burner ignition settings
5.11.3 SETTINGS IN BURN MODE
Table 10. Parameters of pellet burner settings in burn mode
Name
Designation
Limmits
Factory settings
Time for loading
Load
2 – 480 s
60 s
Blowing
Blowing
0 – 10 m
2 m
Time for the emergence of
flame
Fire time
1 – 15 m
8 m
Preheating
Preheat
0 – 180 s
160 s
Fresh air fan
Fan1
20 – 100 %
48 %
Flue gases fan
Fan2
20 – 100 %
100 %
Time for fuel heated
Inflame
60 – 600 s
120 s
Delay before heated
Delay
1 – 240 s
5 s
Tubus work
Tubus work
0 – 100 %
0 %
Name
Designation
Limmits
Factory settings
Time for loading
Load
1 – 240 s
2 – 8 s
Time for burning
Pause
1 – 240 s
14 – 14 s
Fresh air fan
Fan1
20 – 100 %
48 – 100 %
Flue gases fan
Fan2
20 – 100 %
48 – 100 %
Auger 2 delay
Feeder 2 +
0 – 250 s
5 s
Tubus period
Tubus per
0 – 240 s
10 s
Tubus work
Tubus work
0 – 100 %
10 %
Min<Burn>Max
*Load
2 - 8s
Pause
14 - 14s
Fan1
48 - 100 %
Fan2
48 - 100 %
Min<Burn>Max
* Feeder 2 + 5 s
Tubus per
10 s
Tubus work 10 %