1
Manual 101441-001 | Revision A | Publication Date: 12/4/2020
SPECIFICATIONS
Firing Capacities:
Model EHASR-DC
0.75
– 3.00 gal/hr
105,000
– 420,000 Btu/hr Input
Model EH-DC
3.00
– 6.00 gal/hr
420,000
– 840,000 Btu/hr Input
Fuel Pumps
Single Stage Standard
Electrical
Power Supply ……….13.5Vdc, Operating Load w/igniter on: 30 A, w/igniter off: 25A
Motor ………………...13.5Vdc, 3850 rpm, 25 Amps
Ignition ……………….20,000V secondary, Continuous Duty or Interrupted Duty
Note- The electrical specifications shown are maximum current draw; blower wheel and other
components will affect current draw.
WAYNE COMBUSTION SYSTEMS
801 GLASGOW AVE.
FORT WAYNE, IN 46803
PHONE: (260) 425-9200
TOLL FREE: (800) 443-4625
FAX: (260) 345-0341
www.waynecombustion.com
MODEL
EHASR-DC &
EH-DC
OIL BURNERS
Fuels:
Use No.1 or No.2 heating oil (ASTM D-396),
Kerosene, Diesel (ASTM D975-18), JP8
Dimensions (
Standard
):
Height ……………………….…..…..12 1/2”
Width ……………………….…..……15 1/2”
Depth ………………………….……..11 1/2”
Center Line of Tube to Floor .........
8 1/16”
Mounting:
Rigid Flange, Adjustable Flange, or
Pedestal Mount
READ THIS MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THE
INSTRUCTIONS AND SAFETY PRECAUTIONS IN THIS MANUAL CAN RESULT IN SERIOUS
INJURY OR DEATH. KEEP THIS MANUAL FOR FUTURE REFERENCE. INSTALLER: LEAVE
THIS MANUAL WITH THE END USER.
INSTALLATION OF THE BURNER MUST BE DONE BY A QUALIFIED INSTALLER IN
ACCORDANCE WITH REGULATIONS OF THE NATIONAL FIRE PROTECTION AGENCY,
NFPA NO. 31, AND IN COMPLETE ACCORDANCE WITH ALL LOCAL CODES AND
AUTHORITIES HAVING JURISDICTION.
A QUALIFIED INSTALLER IS THE PERSON WHO IS RESPONSIBLE FOR THE INSTALLATION
AND ADJUSTMENT OF THE EQUIPMENT AND WHO IS LICENSED TO INSTALL OIL-
BURNING EQUIPMENT IN ACCORDANCE WITH ALL CODES AND ORDINANCES.
UL File Number: MP98