52
Using RS422(VISCA) / RS485 (PELCO P/D)
You can use RS422/485 port connect to optional controllers, such as joystick control keyboard, control
PC station, to operate the camera.
To perform pan/tilt and zoom operations using the joystick of the control keyboard, and to perform
the Preset operation using the control buttons.
An application software that supports this unit is needed if you use PC station.
RS422 (VISCA) connection
1.
Set RS422 control method on DIP switch.
2.
Set Baud Rate on DIP switch to the same as Baud Rate setting on the keyboard you are using.
3.
Set the specific address for the controlled camera on the DIP switch.
4.
If you want to have the camera address to be automatically assigned by VISCA controller, set the
camera DIP switch address to 0.
5.
Reboot the camera by turning it Off/On after the DIP Switch has been set up correctly.
6.
Use the included RJ45 to RS422 control cable. The controller must be VISCA compatible.
7.
The camera supports Daisy Chain connection of up to 7 cameras.
HDMI Video Signal
SDI Video Signal
Remote Control Signal
(RS422 (VISCA)
or RS485 (Pelco P/D))
IR Remote Controller