15
Video Output
The camera can simultaneously produce SDI and NDI® video output.
SDI Signal
The camera can simultaneously stream SDI video output with NDI® video output.
1.
Connect SDI cable in between the camera your SDI Device/display.
NDI® Signal
The camera can simultaneously stream NDI® video output and SDI video output.
1.
Connect the camera to the network using Cat5/Cat6 network cable.
2.
You need to have a web browser for product configuration.
3.
To obtain NDI® video and configure NDI
®
video, please refer to
Interacting with the Camera
To control and configure your camera, you need to connect with control system (or control keyboard) for
communication by RS-485/RS422. Set up the protocol of communication by control keyboard, the camera can
auto detect VISCA and PELCO-D.
RS485 (PELCO D) control connection diagram
Connect the Camera’s RS485+ and RS485 to RS485/TX+ and RS485/TX- on the control system/keyboard. The
identity of the control system or equipment may be different; the corresponding relationship is as follows:
Camera
(RS485)
1. RX +
2. RX –
Keyboard
(PELCO P/D)
6. TX+
7. TX –
RS485 (PELCO D)
Multiple Cameras Connection
RX +
RX –
RX +
RX –
RX +
RX –
RX +
RX –
CAM1
SYSTEM /
KEYBOARD
(PELCO D)
CAM 2
CAM 3
CAM 255
RS485 PELCO D
System / Keyboard
Connection
TX –
TX +
RX +
RS 485 A
RS 485 +
RS 485 D+
RX –
RS 485 B
RS 485 –
RS 485 D–