17
4.
Use RS422 VISCA protocol can control up to 7 cameras, camera ID from 1 to 7 has to be set.
5.
Supports baud rate of 2400bps, 4800bps, 9600bps and 38400bps.
6.
On the keyboard side, for RS485 control, go into the camera setting menu, select the camera address/ID you
want to set up for, set the baud rate to match the same as the one has been set on camera side, select Pelco
D for RS485 control (please refer to the keyboard manual for instructions on how to configure the keyboard).
7.
On the keyboard side, for VISCA control, select RS232/RS422 control method, set the baud rate to match the
same as the one has been set on camera side.
8.
On the IP control side, use a browser to login go into the camera BirdUI (default set to 192.168.100.100), go to
“Setup>System>Port & Devices” setting page, set the Baud Rate, camera ID, Protocol to the same as the ones
that have been set on the camera side.
9.
Ensure that the SDI and IP video settings of the camera match that of the controller keyboard.
NOTE
•
Regarding the camera ID and Baud Rate setting, for the first communication setting, you must match
the control system (or keyboard) camera ID and Baud Rate setting to the cameras.
•
After communicating successfully in between the camera and the control, you can modify the ID and
baud rate of the camera using the keyboard.
PTZ Control
1
8
9600
None
None
1
PELCO-D
Port Mode
Stop Bits
Data Bits
Baud Rate
Flow Control
Parity
Address Code
PTZ Protocol
Enable Trans-Channel
RS485_1