6.2 

Logging In 

 
 
 

 
The  Login  Page  allows  you  to  Log  into  your  password 
protected  user  account.  The  user  account  saves  your 
protocols,  reports,  and  the  preferences  of  your 
experiments;  it  also  saves  time  by  pre-filling  some 
frequently  used  fields  during  the  experiment  process 
and during reporting. 
 
The  first  step  is  creating  a  user  account.  To  create  a 
new user account, press the 

Add User

 Button. 

 
When the “Add User” button is pressed, the “New User 
Account”  fields  on  the  right  of  the  screen  will  be 
enabled. Upon clicking on any field a pop-up keyboard 
will  appear.  Enter  a  unique  username  and  password 
using  the  keyboard  and  press  “Accept”.  Click  Save  to 
create the user. 
 
Now  you  will  be  able  to  find  your  User  name  on  the 
drop  down  list  at  the  top  left.  The  next  time  you  do  a 
Perifusion  experiment,  just  select  your  user  from  the 
list, enter your pass

word and press “Login”. 

 
 
 
 
 
 
 

Figure 19: Login page 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PERI-4.2

Page 1: ...1 PERIFUSION SYSTEM MODEL No PERI 4 2 ______________________________________________________ USER MANUAL ______________________________________________________...

Page 2: ...YSTEM OVERVIEW 11 5 1 BASIC PERIFUSION SCHEMATIC 11 5 2 VALVE MANIFOLD 12 5 3 PERISTALTIC PUMP 14 5 4 PERIFUSION CHAMBER 14 5 5 COLLECTION TRAY 15 6 PERIFUSION SYSTEM BASICS 16 6 1 POWER UP 16 6 2 LOG...

Page 3: ...ture that accompanies the device This symbol warns of moving parts that may cause personal injury This symbol is used when two people are needed to do the task 1 2 Machine Information In the spaces pr...

Page 4: ...ce with the manufacturer s instructions See Site Preparation in section 1 5 for details 3 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with...

Page 5: ...t The following items are included with the purchase of a Perifusion system Qty Reference Description 1 86610610 Power Cord 12 PERI CASSETTE Pump cassettes 12 PERI CHAMBER Perifusion Chambers 1 PERI T...

Page 6: ...uring the stimulation of pancreatic islets The machine accurately controls temperature flow stimulus source and sample collection in up to 8 channels in parallel The Perifusion system is designed to e...

Page 7: ...7 3 Machine parts identification Figure 3 Perifusion system side view Figure 4 Perifusion system front view...

Page 8: ...tic pump Main pump 4 Temperature control inlet outlets x6 5 Perifusion chamber 6 Sample collection tray 7 Alarm buzzer 8 Tray cooling diaphragm pump 9 Power cable 10 Incubator cover 11 12 Touch Screen...

Page 9: ...ovides the precise resolution needed in perifusion experiments A set of each type is included with this machine Item Description Reference A Silicone Tubing 0 040in ID 0 085in OD 89068 462 B Two Stop...

Page 10: ...oplets 4 L ensure optimal resolution of the dynamic insulin response Figure 8 Perifusion Nozzles 4 5 Collection well plates The collection well plate is where the cell secretions and the perfusate are...

Page 11: ...mperature controlled environment 2 VALVE MANIFOLD An automated valve manifold handles the source selection for each channel The manifold has 8 input channels 1 2 3 8 and four output channels A B C and...

Page 12: ...Minimizing this problem was a priority at the time of developing the new Perifusion system The result was a self contained 32 valves 8 in to 4 out manifold The manifold can change the source for every...

Page 13: ...ected source 0 represents a closed channel Example The manifold state A2 B3 C8 D0 means output A will be from source 2 output B will be from source 3 output C from source 8 and the outputs of channel...

Page 14: ...scription of tubing setup can be found in section 7 5 5 4 Perifusion chamber Sources delivered by the pump will react with the cells inside the perifusion chamber The cells are contained inside the ch...

Page 15: ...itioning mechanism 3 In addition the collection plate can be refrigerated by circulating fluid through the available ports 4 The Perifusion system features a new deep collection tray that allows the u...

Page 16: ...s entirety This machine has been designed with alarm features that will help the user identify and correct potential problems Alarm messages will be displayed at the bottom of the screen A detailed de...

Page 17: ...reate a new user account press the Add User Button When the Add User button is pressed the New User Account fields on the right of the screen will be enabled Upon clicking on any field a pop up keyboa...

Page 18: ...st Page In this page you will also see the User account the Software Version installed in your perfusion machine and the machine Status Bar at the bottom The Status Bar will display any alarms or impo...

Page 19: ...ht This icon should change when the tray is moved between Landscape and Portrait orientations MOTION The motion controls manipulate the position of the tray by enabling direct access to the motors Sim...

Page 20: ...valuable sub system for automating a Perifusion experiment It is composed by the precision peristaltic pump and the 8 to 4 manifold The pump can be tested by assigning a value to the Pump Flow rate b...

Page 21: ...structions on operating Orbitor enabled machines TIMING The timing controls are used for special protocol execution sequences ACTION REQUIRED ALARM If the user does not want or can t use the automatic...

Page 22: ...confirming your choice and reminding you the positions of the chambers in the chamber rack inside the incubator As a general rule chambers should be placed on the rack starting from the right most po...

Page 23: ...een you will find a of Plates This number will tell you the number of well plates required to complete the protocol This will help you have all the plates in hand to avoid unnecessary delays Creating...

Page 24: ...to the inlet tube of the top cap 9 Repeat for all chambers being used You should end up with two halves as shown in Figure 2 of the screen Figure 29 Perifusion Chamber Assembly Once you have both hal...

Page 25: ...ve protocol You will be able to monitor the valve sequence followed by the machine as it performs the priming The progress will be displayed on the bottom bar Figure 31 Priming page 7 7 Cell loading W...

Page 26: ...ontrol Once the system has been prepared the incubator must be heated up to the desired temperature and the collection tray must be cooled down to preserve the analytes Follow the on screen instructio...

Page 27: ...en you reach this screen the cells should be in the chambers the manifold and should be primed with the input solutions and the temperature of the incubator and tray should be at their set points On t...

Page 28: ...low you to load a 96 well plate into the sample tray Press the PLAY button once more to begin the protocol Figure 37 Execution Controls ALARMS AND INDICATORS This section of the protocol monitor displ...

Page 29: ...he timing and progression of the experiment Since the experiment has many chronological levels these indicators will help you identify where you are in your protocol The first level locates you in the...

Page 30: ...30 AUC Area Under Curve...

Page 31: ...the chamber from the micro centrifuge tube 6 Close the lid of the micro centrifuge tube 7 Centrifuge at 300g for 5 minutes 8 Aspirate the supernatant leaving beads and islets behind At this point the...

Page 32: ...mixture of 9 parts distilled water and 1 part bleach based disinfectant 3 Rinse once more with de ionized water 4 Dry by drawing air remove input tubing from the manifold Figure 43 Cleaning page Durin...

Page 33: ...sed The plate maps are in tabular form representing the 96 well plate 8 x 12 and each cell represents an individual well Each cell contains two pieces of information The color indicates which solution...

Page 34: ...ng the above solutions the pH 7 08 8 Bring volume to 200ml with ddH2O 9 Add 0 4g 0 2 of BSA Sigma Cat A7888 OR A6003 10 Filter Sterilize through 0 22 filter Notes a When making Solution 2 dissolve CaC...

Page 35: ...kept refrigerated for up to 4 weeks Bead Suspension Use Follow these instructions before using the bead suspension in a perifusion chamber preparation Warm bead suspension to 37 using an incubator or...

Reviews: