background image

18

Selecting purified water - 

Only processed through purification treatment, the water will go through the electrolysis process. 

Indication of operation 

in progress

Purified water indicating button

1. Open the water supply control valve to let the water flow in to generate the alkaline ionized

water of the set value.

2. Push the purified water indicating button. 

- Indication light for purified water selection 

Voice guidance: Crystal clear water on production.

3. Use the purified water. 
4. When the water supply control valve is turned off in the middle of the water being used, the

selection of the purified water is called off and the setting will be restored back to the
previously set value of  Alkaline . In order to stop the operation in the middle of the use,
other selection buttons need to be pushed to select other functions.

When the indication light for the purified water is turned off.

When there is a change in the water pressure leading to the lowering of the water level,

the indication light will be turned off and the setting will be restored back to the previously
set value of ‘Alkaline’.  Use the product by setting the value again after adjusting the
water pressure. 

Caution

Acidic ionized water is not for drinking, so do not drink it. 

Use the water after letting the water flow through for about 5 seconds right after the generation is initiated. 
Use the water initially daily after letting the water flow through for 10 ~ 15 seconds by opening the
water tap completely.
Use the water after letting the water flow through for more than 30 seconds when using the product  

after not using it for a few days.

Should not remove the purification filter when letting the water flow through the main case.
Do not drink the drained water following the automatic Self-Cleaning, and the acidic water.

Summary of Contents for BTM-505N

Page 1: ...r to the manual whenever necessary Our company will not be held responsible for any malfunction or accident resulting from incorrect installation or improper handling Note There is a protection film o...

Page 2: ...reparations 6 3 How to install 8 Installation precautions 8 How to install 9 4 Before using the product 13 Precautions for using the product 13 Using the product appropriately for each purpose 14 How...

Page 3: ...sed the warranty service will not be provided 3 Components Wall hanging Nails and Fuse Hose pH Comparison Sheet Flexible Alkaline Faucet Hose Band pH Test Solution 7x9 PVC hoses 70cm 1 4 standard hose...

Page 4: ...e acidic ion0ized water flows out Alkaline ionized water flows out when the acidity is chosen 8 Inlet Supplys the source water to the product 9 Wall hanging Hole Hangs the product on the wall using na...

Page 5: ...nly Alkaline ionized water selection button Button for selecting the alkaline ionized water Indicating the errors for Overheated electrolytic bath Failed self cleaning Excessive water cleaning flow Co...

Page 6: ...tion of the symbol marks Warning Indicates that injury to the body or damage to the property can be caused if you use the product wrongly because of your disregard for the items Caution Disassembly to...

Page 7: ...when inserting it into the wall socket or removing it from the socket Damage to the electric cord fires or electrical shocks can be caused when if the cord is pulled Clean the wall socket after remov...

Page 8: ...a place full of moisture or dusts If not followed damage to the product or risk to your safety can be caused If not followed damage to the product or risk to your safety can be caused Should hold the...

Page 9: ...r Single water tap 4 Install the standard compliant adapter Included Select between large and medium small 3 8 between the water pipe and the water branch pipe Then install the adapter which needs to...

Page 10: ...ndard connection hose 1 4 to the adapter installed with one touch fitting of union Drawing 3 4 Insert the inlet hose deepest into the one touch fitting and insert the safety pin as in drawing Pls chec...

Page 11: ...ater tap Take the little screen out Cold water inlet Nut Cold water inlet Nut Cold water inlet Nut Tighten the screws with screw driver after inserting the rubber seal Water flows into ionizer when th...

Page 12: ...e for installation and the adapter installed to the water tap and then cut the hose with an extra length 2 Cut the PVC hose for the acidic water into the length of 50 70cm and place it lower than the...

Page 13: ...13 Danger To reduce the risk of electrocutions Precautions for use Warning To reduce the risk of burns electrocution fire or injury to persons Important safeguards...

Page 14: ...insing By selecting the acidic water button In places where the water hardness is high or compounds of calcium are abundant there can be white sedimentation inside the case requiring additional purify...

Page 15: ...s Contact the sales shop or the main office for advice when the generated water smells Do not drop the product or apply strong impact to it Dropping or impact can cause malfunctioning Do not block the...

Page 16: ...and consult a doctor if you feel abnormality after drinking the water or if there is no alleviation of symptoms felt in the stomach even after continuously drinking the water Those people who currentl...

Page 17: ...are required to adjust and keep the water pressure to make the indication light stay on at the center of the standard level When the indication light stays on at the standard level about 1 5 0 5 Min o...

Page 18: ...ed to select other functions When the indication light for the purified water is turned off When there is a change in the water pressure leading to the lowering of the water level the indication light...

Page 19: ...essure to meet the standard water flow volume 1 5 0 5 Min according to the ionized water generation method The pH values can varies depending on the quality of water and the flow volume Materials to b...

Page 20: ...ut 2 3 minutes Dusts of activated carbon which is the filtering medium may flow mixed together with water during the initial flow after the filter is replaced Check whether there is any water leakage...

Page 21: ...ing this metod the pH of the ionized water will be resume higher because the water is now coming in direct contact with the cleaned electrodes Symptom of calcium scale when whitish floating substances...

Page 22: ...22 How to use cleansing filter...

Page 23: ...the items for your safety Do not use the following type of water Acidic water Water drained after self cleaning Water tested with the pH reagent Water collected at the start of production About 1 2 c...

Page 24: ...lotion Floral arrangement When the acidic water diluted 1 2 is applied to the cut part of the flowers it will keep the flowers fresh for a longer period of time Water for parboiling noodles When the...

Page 25: ...o be disconnected from the main body packed into a vinylpackage and stored in a refrigerator Disconnect the electric plug When you start to use the system newly after the period you need to replace th...

Page 26: ...e using the alkaline ionized water Rice can be sticky depending on the volume of water kinds of rice and kinds of r ice cooking appliance Use the water after setting the appropriate stage of ionized w...

Page 27: ...generated when pushing the button lightly The beeping sound means that there are no problems with the fuse It is because of the bimetallic safety system for the overheating inside the system in case o...

Page 28: ...the filter is a genuine one made by the company If a unbranded filter is installed there will be a voice guidance saying Filter rejected mount correet one and the power will be turned off after 20 se...

Page 29: ...en the water flows through initially the water can become warm due to the room temperature or the heat inside the main body Not malfunctioning Use the water after let the water flow through For about...

Page 30: ...acidic reaction occur in an opposite way so it is understood that the alkaline ionized water is generated also if there is acidic reaction taking place We can simply say that the symptom is the result...

Page 31: ...4gal min 0 1gal Max 3 3 min 0 8gal min Alkaline Acidic 5 steps 2 steps Double Automatic Reverse Cleaning and manual cleaning Platinum titanium electrodes Cartridge type 2Stage 1st Approx 3000 2st App...

Page 32: ...se due to manufacturing defect If a replaced product requires major repair within a month of replacement Reparable Not reparable If repair is impossible due to lack of parts The company should carry p...

Page 33: ...f purchase Please write down the date of purchase on the warranty If the date of purchase cannot be confirmed free service is not provided 3 This warranty is not reissued Keep it in a safe place toget...

Page 34: ...34 MEMO...

Page 35: ...35 MEMO...

Page 36: ...ong Gunpo si Gyeonggi do Korea Tel 82 31 459 3853 Fax 82 31 429 3859 E mail btm biontech biz http www bion tech com Korean http www biontech biz International These instruction shall also be available...

Reviews: