TX-KFP
Bionics Instrument
© 2004 Eur 20040426, all rights reserved
- 21 -
Fig. 3.2.6
CN2
PC-5028
1 2 3 4 5
Hole
Positioning
3. Installation
3.2.1 Wall- or ceiling-mounting of the gas detection unit (Cont’d)
1
2
3
4
8
5
6
7
9
Fig. 3.2.5
1 – Ceiling mounting plate
2 – Wall mounting plate
3 – Side/Top cable entry (PG-7)
4 – Holder top cover
5 – Holder bottom part
6 – Holder connecting ring
7 – Holder bottom cover
8 – PC-5028 connector board
(incl. St.St. mounting plate)
9 – TX-KFP unit
With the top part in place unscrew the holder
connecting ring (item 6) to release the PC-5028
board including the stainless steel mounting plate
(item 8).
Feed the controller/signal cable through the cable
entry grommet (item 3) and connect the cable to
connector CN2 (see section 3.3 for wiring details).
Remount the PC-5028 board.
Make sure that the locking pin fits into the
positioning hole of the stainless steel mounting
plate (see fig. 3.2.6).
Re-fit the holder connecting ring and plug the TX-
KFP unit (item 9) into the SGR 60 DIN connector.
Screw-on the holder bottom part to secure the unit
in the holder.
Note:
To accommodate the most practical cable routing
the PG-7 cable entry grommet (3) in the top cover
can be either top or side mounted.