background image

ASSURANCE

 

GDS®

 

PPMX

 

USER

 

MANUAL

 

12 

Front

 

Panel

 

Connections

 

The

 

PPMX

 

has

 

two

 

functional

 

USB

 

host

 

ports

 

on

 

the

 

front

 

panel.

 

The

 

USB

 

ports

 

can

 

be

 

used

 

to

 

connect

 

USB

 

drives

 

(which

 

can

 

also

 

be

 

seen

 

by

 

the

 

tablet/laptop

 

when

 

plugged

 

into

 

the

 

PPMX),

 

keyboard,

 

mouse,

 

or

 

any

 

other

 

compatible

 

device

 

(heater/chiller,

 

barcode

 

scanner

 

or

 

shaker,

 

for

 

example).

 

 

In

 

a

 

situation

 

where

 

an

 

emergency

 

stop

 

is

 

required,

 

pressing

 

the

 

STOP

 

button

 

stops

 

the

 

PPMX

 

immediately.

 

The

 

protocol

 

stops

 

and

 

results

 

are

 

displayed

 

(after

 

touching

 

OK

 

on

 

the

 

prompt).

 

 

1

 

USB

 

host

 

2

 

STOP

 

 

 

UPS

 

Battery

 

Power

 

and

 

Line

 

Conditioner

  

To

 

prevent

 

fluctuations

 

in

 

power

 

to

 

the

 

PPMX

 

and

 

tablet/laptop,

 

it

 

is

 

recommended

 

that

 

the

 

following

 

UPS

 

battery

 

backup

 

be

 

used

 

with

 

the

 

system:

 

 

Tripp

 

Lite

 

SU750XL or equivalent

 

 

Additionally,

 

it

 

is

 

recommended

 

that

 

the

 

PPMX

 

be

 

placed

 

on

 

a

 

separate

 

circuit

 

from

 

other

 

equipment.

 

 

Power

 

On

 

and

 

Start

 

Up

 

To

 

start

 

the

 

PPMX:

 

 

1

 

Make

 

sure

 

that

 

the

 

PPMX

 

is

 

connected

 

to

 

the

 

external

 

power

 

supply

 

and

 

that

 

the

 

external

 

power

 

supply

 

is

 

connected

 

to

 

a

 

power

 

source.

 

2

 

Turn

 

power

 

on

 

at

 

the

 

external

 

power

 

supply

 

(O

 

is

 

off,

 

I

 

is

 

on).

 

3

 

Turn

 

the

 

PPMX

 

power

 

on

 

using

 

the

 

MAINS

 

power

 

switch

 

located

 

on

 

the

 

rear

 

panel.

 

The

 

indicator

 

light

 

on

 

the

 

front

 

panel

 

will

 

illuminate

 

green.

 

4

 

Connect

 

the

 

control

 

tablet/laptop

 

to

 

the

 

PPMX

 

and

 

power

 

it

 

on.

 

5

 

Close

 

the

 

rotating

 

cover

 

door.

 

The

 

PPMX

 

will

 

not

 

operate

 

with

 

the

 

cover

 

open.

 

 

Log

 

In

 

 

When

 

prompted,

 

enter

 

the

 

“User

 

name”

 

and

 

“Password”,

 

and

 

then

 

select

 

Accept

 

(or

 

the

 

X

 

to

 

cancel).

  

Password

 

is

 

case

sensitive.

  

It

 

is

 

recommended

 

to

 

change

 

the

 

password

 

for

 

the

 

default

 

Administrator

 

(admin)

.

   

 

1

 

Select

 

the

 

“User

 

name

 

(Full

 

name)”

 

in

 

software

 

to

 

go

 

to

 

the

 

“User

 

properties”

 

screen.

 

2

 

Enter

 

a

 

new

 

Password

 

for

 

the

 

user,

 

and

 

then

 

enter

 

the

 

password

 

again

 

in

 

the

 

“Password

 

confirm”

 

field.

 

3

 

Select

 

Save

,

 

or

 

Back

 

to

 

return

 

to

 

the

 

previous

 

screen

 

without

 

saving.

  

 

The

 

default

 

User

 

name

 

is

 

admin

 

and

 

the

 

Password

 

is

 

Gilson268

 

 

Summary of Contents for Assurance GDS PPMX

Page 1: ...55240 R003 082016 ASSURANCE GDS PPMX USER MANUAL 12822 SE 32nd Street Bellevue WA USA 98005 Phone 425 603 1123 Fax 425 603 0070 info biocontrolsys com www biocontrolsys com...

Page 2: ...nt Documentation Protocols Disposables Technical Specifications III Setup Operation 9 Unpacking Removable Tray Rear Panel Connections Front Panel Connections UPS Battery Power and Line Conditioner Pow...

Page 3: ...tocol after Communication Loss Hood Open Reporting an Error Technical Services V Maintenance 25 Cleaning Pipette Head Calibration Alignment Calibration Preventative Maintenance Warranty Instrument Ret...

Page 4: ...ASSURANCE GDS PPMX USER MANUAL 3 Best Practices XII Appendix G 35 Pack Up XIII Appendix H 39 Ordering Information...

Page 5: ...fety standards of design manufacture and intended use of the instrument BioControl Systems assumes no liability for the customer s failure to comply with these requirements The PPMX has been certified...

Page 6: ...ntainer The tip waste container should be emptied in accordance with national and local safety regulations Tray The moving tray is capable of causing injury by pinching For an instrument with the rota...

Page 7: ...This user manual is intended to assist PPMX users with system start up basic operation maintenance and service Standard Equipment After the PPMX and accessories are unpacked the following items shoul...

Page 8: ...son Installation and Operational Qualification IQ OQ Procedures Gilson Declaration of Conformity Gilson Validation Certificate for TRILUTION micro Gilson Quality Control Report Pipette Head Protocols...

Page 9: ...3 1 cm 21 4 X 25 8 X 20 9 in 24 9 kg 55 lbs Environmental Conditions Indoor use Altitude up to 2000 m Temperature range 5 C 40 C Humidity Maximum relative humidity 80 for temperatures up to 31 C decre...

Page 10: ...a 9 16 wrench if needed Lift straight up using handles on both sides 2 Remove the two grey foam pieces 3 Remove the closed and open ended cardboard accessories boxes by sliding them out from the bunge...

Page 11: ...tray onto the metal carrier It is keyed and will only mount one way Observe that the tray is level and fully seated on the metal carrier Rear Panel Connections Refer to the diagrams on the next page...

Page 12: ...RS 232 and HDMI are not supported 1 Input Output Green 2 USB host Not Supported 3 USB host 4 Ethernet Not Supported 5 USB device 6 RS 232 Not Supported 7 HDMI Not Supported 8 Powerreceptacle 9 Power...

Page 13: ...quipment Power On and Start Up To start the PPMX 1 Make sure that the PPMX is connected to the external power supply and that the external power supply is connected to a power source 2 Turn power on a...

Page 14: ...r the user The full name can be from 1 to 100 characters in length must begin with an English letter or number and may contain the following special characters _ and Spaces are valid 3 Optionally ente...

Page 15: ...between the PPMX and control tablet if the battery runs too low Refer to the table below for a description of the icons used in the on screen keyboard The following icons appear on several screens in...

Page 16: ...fere with the alignment Ensure that the clips are positioned as shown in the diagram below and that the thumbscrews have been tightened 4 Close the rotating cover 5 The tablet starts TRILUTION micro a...

Page 17: ...l heads When finished adding heads select Back Set Date Time Set the date and time to ensure a correct date time stamp on protocol runs This should only have to be done once On the Settings menu selec...

Page 18: ...ecks that the PPMX is connected If connected the software goes to the next screen If not connected a message will appear suggesting possible solutions 5 Enter sample number kit and reagent information...

Page 19: ...ew for each clip 2 Place the tip rack on the removable tray with the beveled corner in the back left corner 3 Rotate each clip so that it will effectively secure the tip rack on the tray as shown in t...

Page 20: ...with the slide bar on the left side Slice the amp tubes and expand the plate prior to adding the lid 15 If individual sample IDs need to be entered for each sample in the sample block this can be don...

Page 21: ...en The colors indicate the following information Red Negative volume Green Volume in the tube or well Blue Empty tube or well Pink Tips 6 The top of the screen shows the status the name of the protoco...

Page 22: ...inganetwork enabled laptop ToimportdatafromaLIMSsystem thefollowingsteps shouldbefollowed 1 SelectStartutility 2 SelectLIMSAssistant 3 SelectIMPORT 4 Browseto selecttheLIMSimportfileforthePPMXprotocol...

Page 23: ...ct Export 5 Browse for and select the destination USB drive for the protocol file and then select Open The protocol is saved to the location with a SQLITE extension Delete Protocol To delete a protoco...

Page 24: ...the PPMX 7 Power the PPMX on first 8 Power the computer on 9 Proceed with selecting Run a protocol to check communication has been re established Re starting a Protocol after Communication Loss If dur...

Page 25: ...portant for Technical Services to be able to adequately diagnose the issue 2 From the error message select Manual control 3 Check the box Home in recovery mode and select Home XYZ 4 Pipette should ret...

Page 26: ...g Block s HT Amp Tube Block and Lid if applicable should be cleaned by lightly spraying a paper towel with 10 bleach solution and wiping the outside surface Follow with 70 isopropyl alcohol as describ...

Page 27: ...r 10 Re alignment of system Contact BioControl Systems Technical Services at 425 603 1123 or techservices biocontrolsys com to schedule To help us serve you quickly and efficiently please refer to App...

Page 28: ...PWR AND USB CABLING KIT 79121 BLACK PLUG FOR BACK COVER 79131 ALLEN WRENCH 5 MM 79101 REMOVABLE TRAY 96 WELL 79105 PIPETTE TIP RELOAD RACK 79173 PICKPEN TIP RELOAD RACK 79109 TIP DISPOSAL BIN 79103 AS...

Page 29: ...REAGENT RESERVOIR CASE OF 25 79119 1 COLUMN REAGENT RESERVOIR CASE OF 25 73087 ASSURANCE GDS PICKPEN II TIPS RACKED 73085 ASSURANCE GDS PICKPEN II TIPS BULK 73004 ADHESIVE FILM SHEETS BOX OF 100 7302...

Page 30: ...he PickPen magnetic head is located on the back outside casing o The serial number for the control tablet is located on the outside of the box o The serial number for the Surface laptop is located beh...

Page 31: ...ASSURANCE GDS PPMX USER MANUAL 30 Appendix C Maintenance Log...

Page 32: ...tion and testing BioControl shall repair or replace within 5 days of receipt by BioControl any such equipment found to be defective and promptly return such equipment to Buyer transportation and insur...

Page 33: ...rompt 11 When run is completed weigh both filled GDS Sample Bases and the filled GDS Resuspension Plate and record weight NOTE The protocol will fill the CR and Resuspension Buffer 5x the standard amo...

Page 34: ...ps 200 L filter 3 Reagent reservoir a Wash b c Empty d RS Buffer 4 Sample block 1 1 48 CR 5 Empty 6 Sample block 3 1 48 Wash 7 Reagent holder a Std or b HT CR bottle 8 RS plate 1 1 48 RS Buffer skippe...

Page 35: ...3 is for sterile media BHI or DFB o Column 4 is for Resuspension Buffer Tq Re cap Concentration Reagent bottles after each run to prevent evaporative loss and store under refrigeration Cover reservoir...

Page 36: ...d box and put into the accessories box 5 Place all the deck accessories into their respective plastic bags and place into the accessories box a Trash bin tip reload racks tip puck reagent holder and p...

Page 37: ...n the base and press the white foam block into the opening to prevent the sheet from moving during shipping 11 Tape the Alignment Head cable to the foam block 12 Install the shipping bracket to the ar...

Page 38: ...down when lifting PPMX to prevent damage from the lid crashing forward 16 Rotate the clear cover open until it catches on the magnets using lab tape secure tbe lower cover to the upper cover 17 Place...

Page 39: ...or additional protection 22 Gently lower the crate lid over the PPMX unit being careful not to loosen the grey foam pieces This step requires 2 people 23 Attach the 4 bolts to the bottom of the crate...

Page 40: ...or Listeria spp Tq The following kits are sold separately but are required for the ATM kit Wash Solution Part No Description 61031 100 GDS Wash Kit 4 x 250 mL RS Buffer Part No Description 34724 100C...

Reviews: