background image

2

TABLE OF CONTENTS

SAFETY WARNINGS .......................................................................................................................................................................3
SAFETY INSTRUCTIONS ..............................................................................................................................................................3
SAFETY LABELING ........................................................................................................................................................................3
CAUTION ...........................................................................................................................................................................................3
PRODUCT APPLICATION .............................................................................................................................................................4

C

onstruCtion

 ....................................................................................................................................................................................................

4

P

rinCiPle

 

of

 o

Peration

 ....................................................................................................................................................................................

4

l

imitation

 

of

 u

se

 ..............................................................................................................................................................................................

4

W

ater

 Q

uality

 .................................................................................................................................................................................................

4

INSTALLATION ...............................................................................................................................................................................5

l

oCation

 .........................................................................................................................................................................................5

s

addle

 V

alVe

 i

nstallation

 ............................................................................................................................................................6

f

auCet

 i

nstallation

 ................................................................................................................................................................... 6-7

s

ystem

 i

nstallation

 ................................................................................................................................................................... 7-8

t

ubing

 i

nstallation

 .......................................................................................................................................................................9

t

ubing

 r

emoVal

 .............................................................................................................................................................................9

t

eChniCal

 a

ssistanCe

 .....................................................................................................................................................................9

r

eCommended

 o

Ptions

....................................................................................................................................................................9

MAINTENANCE .............................................................................................................................................................................10

i

nsPeCtion

 .....................................................................................................................................................................................10

f

ilter

 C

artridge

 r

ePlaCement

 ....................................................................................................................................................10

l

amP

 i

nstallation

 

or

 r

ePlaCement

 .............................................................................................................................................11

Q

uartz

 s

leeVe

 i

nstallation

, C

leaning

 

or

 r

ePlaCement

 ............................................................................................................

12

r

ePlaCement

 

of

 b

roken

 Q

uartz

 s

leeVe

 ................................................................................................................................

13-14

d

isPosal

 

of

 m

erCury

 a

dded

 l

amP

 ..............................................................................................................................................14

TROUBLESHOOTING ..................................................................................................................................................................14
TECHNICAL SPECIFICATIONS .................................................................................................................................................15
DIMENSIONAL DATA ...................................................................................................................................................................16
REPLACEMENT PARTS ...............................................................................................................................................................17

Bio-Logic

®

 

BIO-1.5

 Ultraviolet Water Purifier .........................................................................................................................17

Pure Water Pack

TM

 ...................................................................................................................................................................18

MAINTENANCE NOTES ..............................................................................................................................................................19
USER ASSISTANCE .......................................................................................................................................................................20
PRODUCT REGISTRATION ........................................................................................................................................................20
WARRANTY ....................................................................................................................................................................................20

P

atent

 n

otiCe

 ...............................................................................................................................................................................20

These instructions generally describe the installation, operation and maintenance of the 

Bio-Logic

®

 

 

Pure Water Pack

TM

 

Questions that are not specifically answered by these instructions should be directed to the Factory.
Atlantic Ultraviolet Corporation

®

 takes all possible precautions when packaging equipment to prevent damage. 

Carefully inspect and report all damage upon receipt of product. Do not install damaged equipment.
Follow all instructions on all labels and tags. Carefully inspect all packing materials 

before discarding to prevent the loss of accessories, mounting hardware, 

spare parts or instructions.

The information and recommendations contained in this publication are based upon data 

collected by the Atlantic Ultraviolet Corporation

®

 and are believed to be correct. However, no 

guarantee or warranty of any kind, expressed or implied, is made with respect to the information 

contained herein. Specifications and information are subject to change without notice.

Summary of Contents for PURE WATER PACK BIO 1.5 PWP

Page 1: ...SA Models Ballast 120v 50 60 Hz Ballast 230v 50 60Hz BIO 1 5 PWP 10 0518A 10 0514A Extensive Product Information Available at ultraviolet com buyultraviolet com Installation Operation Maintenance Read...

Page 2: ...ISTRATION 20 WARRANTY 20 Patent Notice 20 These instructions generally describe the installation operation and maintenance of the Bio Logic Pure Water PackTM Questions that are not specifically answer...

Page 3: ...to determine and validate the suitability of this equipment for use in the user s system or process No warranty or representation is made by the manufacturer with respect to suitability or performanc...

Page 4: ...osing it to the germicidal lamp Exposure time is related to the flow rate the higher the flow rate the lower the exposure time or the lower the flow rate the higher the exposure time The ultraviolet i...

Page 5: ...ter purifier MUST be connected to the cold water line only 5 The system should be located as close to the faucet as possible This eliminates the possibility of the purified water being re contaminated...

Page 6: ...til it is firmly seated The valve is CLOSED in this position 4 Open the cold water supply valve or main valve check for any signs of leaks around valve connection 5 Install John GuestTM Tubing Connect...

Page 7: ...r b Run the precut 24 tubing from the outlet of the carbon filter to the inlet of the Bio Logic water purifier c Run the tubing from the faucet to the outlet of the Bio Logic water purifier Measure cu...

Page 8: ...ter to run for 10 minutes to flush the filter and system Figure 4 Bio Logic Pure Water PackTM Install 9 Plug ballast into an approved Ground Fault Circuit Interrupt GFCI receptacle Where a 2 prong or...

Page 9: ...let Corporation maintains a qualified team of application specialists that can provide any technical assistance which maybe required during the use of this system For any questions concerns or technic...

Page 10: ...dal lamp operation This provides an indication of lamp operation and does not indicate the level of ultraviolet intensity or transmission through the water 2 To ensure proper operation of the Bio Logi...

Page 11: ...ir bubbles Turn off the faucet and check between the filter housing and head for leaks 12 It is recommended when installing a new carbon filter to allow the water to run for 10 minutes to flush the fi...

Page 12: ...so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so...

Page 13: ...Carefully discard all pieces of the broken quartz sleeve 8 Inspect the large O Ring used to seal the chamber and the chamber head Make sure the O Ring is seated properly between the chamber head ring...

Page 14: ...power Verify that the purifier is connected to a live power source Water leaking from purifier Cracked or broken quartz sleeve Shut down purifier drain and replace quartz sleeve See Quartz Sleeve Ins...

Page 15: ...Rate GPM 1 5 Inlet Outlet Size 1 4 Tubing to 3 8 MNPT John GuestTM Connector Number of Lamps 1 Lamp Model No 05 1366 R Quartz Sleeve Yes Length 14 1 2 Width 5 3 4 Height 18 Shipping Weight 18 Lbs Vol...

Page 16: ...16 DIMENSIONAL DATA Figure 10 Dimensional Data All specifications dimensional data etc are approximate and subject to change without notice...

Page 17: ...TM Ballast 12v DC 1 10 1201A 3 STER L RAY Lamp 1 05 1366 R 4 Static Gland Nut 2 25 1492D 5 Teflon Washer 2 25 3023A 6 Rubber O Ring Quartz Sleeve 2 00 1023A 7 CRYSTAL CLEARTM Quartz Sleeve 1 15 1700A...

Page 18: ...7 6 Screw 10 16 x Long 8 50 0096 7 Filter Cartridge 5 Micron Pleated 1 25 4508 8 Filter Cartridge Carbon 1 25 4509 9 Male Connector x3 8 NPTF John GuestTM 4 25 4513 10 Pipe Nipple 3 8 x1 Long PVC 1 25...

Page 19: ...19 MAINTENANCE NOTES...

Page 20: ...attempt has been made to determine the patent status of applications illustrated or described in this publication Inclusion in this publication of any design or method of use which may be patented is...

Reviews: