36
MPR180416 Rev. B
www.bindicator.com
Code/Icon
Meaning
Corrective Action
S:17
Calibration interval as defined in Mainte-
nance Required Limit has expired.
•
Perform calibration
S:18
Calibration interval as defined in Mainte-
nance Demanded Limit has expired.
•
Perform calibration
S:25
Internal error
•
Reset power. If fault persists, contact Bindicator
S:27
Internal device failure caused by an External
RAM memory error.
•
Repair required, contact Bindicator
S:28
Internal device failure caused by a RAM
memory error.
•
Repair required, contact Bindicator
S:29
EEPROM damaged
•
Repair required, contact Bindicator
S:30
EEPROM corrupt
•
Reset power. If fault persists, contact Bindicator
S:31
Flash error
•
Repair required, contact Bindicator
S:33
Factory calibration for the internal
temperature sensor has been lost.
•
Repair required: contact Bindicator.
S:34
Factory calibration for the device has
been lost.
•
Repair required: contact Bindicator.
S:48
User configuration is invalid. One or more
of parameters: Low Calibration Point, High
Calibration Point, Volume breakpoints, and/
or Auto False-Echo Suppression, are set to
invalid values.
•
Reconfigure the unit.
•
Ensure the difference between High Cali-bration
Point and Low Calibration Point is not less than or
equal to zero; do a Master Reset.
S:52
Fail-Safe is activated. Possible causes:
1. hardware failure
2. memory failure
3. Fail-safe LOE timer expired-possible
causes: faulty installation, antenna material
build-up, foaming/other adverse process
conditions, invalid calibration range
•
For 1 and 2: if fault persists, contact Bindicator
•
For 3:
• Correct configuration; ensure installation is correct
• No antenna build-up
• Adjust process conditions to minimize adverse
conditions
• Correct calibration range
S:54
Fault occurs when the PV exceeds the user
configured min./max. range for mA output.
•
Adjust process to fall within limits of min./max. mA
values or adjust limits of mA if possible.
S:66 to S:83
Device error. NOTE fault text and icons
appear only on LCD
•
Repair required, contact Bindicator
S:94
Device error. Possible causes:
1. Voltage too low
2. Hardware defect
•
For 1: Confirm voltage is within specifications and
modify wiring or increase source voltage accordingly
•
For 2: Require required, contact Bindicator
S:95 to 97
Device error. NOTE fault text and icons
appear only on LCD
•
Repair required, contact Bindicator
S:98 to 108
Device error. NOTE fault text and icons
appear only on LCD
•
Repair required, contact Bindicator
S:109 to 112
Device error. NOTE fault text and icons
appear only on LCD
•
Repair required, contact Bindicator