5
www.bindicator.com
MPR180416 Rev. B
FUNCTIONAL
Power Supply
Nominal 24 VDC with max 550 Ohm loop resistence; Maximum 30 VDC
Dead Zone
15.7 in. (400 mm) from mounting plate
Measurable Distance
131 ft (40 m) or 328 ft (100 m)
Transmitting frequency
78 to 79 GHz FMCW
Update Time
Maximum 10 seconds (depending on Settings)
Beam angle
4 degrees
PERFORMANCE
Accuracy
0.2 in. (5mm)* including hysteresis and non-repeatability
Ambient Temperature
-40 to 175 °F (-40 to 80 °C)
Ambient Pressure
12 to 15 psi ( 860 to 1060 mbar)
Process Temperature
-40 to 392 °F (-40 to 200 °C)
Output signal
4 to 20 mA
HART Communication
Load
230 to 550 Ohm; 230 to 500 Ohm when connecting a coupling module
Maximum Line Length
4921 ft (1500 m) multi-wire
Humidity
45 to 75% relative humidity
Dielectric Constant
Minimum dK of 1.6 for ranges up to 65.6 ft (20 m)
Minimum dk of 2.5 for ranges up to 328 ft (100 m)
PHYSICAL
Material
316 Stainless Steel with polyurethane powder coat finish
Protection
Type 4X/NEMA 4X; Type 6/NEMA 6, IP68
Conduit Entry
1/2” NPT
Mass
6.94 lb (3.15 kg) (with 3” SS flange)
Mounting
4, 6 or 8 in. flange or aiming flange
ENVIRONMENTAL
Location
Indoor/outdoor
Altitude
16,404 ft (5000 m) max
Installation Category
I
Pollution Degree
4
*Under severe EMI/EMC environments per IEC61326-1 or NAMUR NE21, the device error may increase to a maximum of 1”
(25 mm)
APPROVALS & RATINGS
FM and CSA
Hazardous: Dust Ignition Proof: Class II, Div1, Groups E, F, G; Class III T4
Hazardous: Non-incendive: Class I, Div 2, Groups A, B, C, D, T4
CE
Electromagnetic Compatibility Directive
Low Voltage Directive