8’–24’ POWERFOIL
®
X2.0 WASHDOWN & POWERFOIL
®
X2.0PLUS WASHDOWN
53
WWW.BIGASSFANS.COM ©2012 DELTA T CORP. ALL RIGHTS RESERVED
8’–24’ POWERFOIL
®
X2.0 WASHDOWN & POWERFOIL
®
X2.0PLUS WASHDOWN
Error code
Description and corrective action
Internal Memory Error
If the power cycle is not resolved, perform a parameter hard reset. If the condition persists, contact
Customer Service.
Communications Error—Slave
Verify proper data wiring between the drive’s RS485 port and the command source.
Base Block
Base Block input (M4) has been triggered.
Check the accessory wiring and accessory configuration. The drive will auto-recover to the
previous operating state.
Feedback Signal Error
Check the AVI/ACI wiring.
Various Unrecoverable Errors
If the power cycle will not clear these faults, contact Customer Service.
Pr.00.04 Diagnostics running display options
Setting
Run screen display
00
(BAF Default) Display user-defined unit
01
Counter value; pulses on TRG terminal
02
Not valid
03
DC buss voltage (÷ 1.414 = approx. AC line)
04
RMS equivalent feedback level (percentage)
05
PID analog feedback level (percentage)
06
Power factor angle of motor (degrees)
07
Output power in kW
08
Motor torque estimate (N·m)
09
VDC at AVI terminal (displayed in volts)
10
mA at ACI terminal (displayed in mA)
11
IGBT temperature (degrees C
°
)
12
Not valid
13
Not valid
14
Not valid
15
Not valid
E Series fan error codes (cont.)
Troubleshooting (cont.)