8’–24’ POWERFOIL
®
X2.0 WASHDOWN & POWERFOIL
®
X2.0PLUS WASHDOWN
15
WWW.BIGASSFANS.COM ©2012 DELTA T CORP. ALL RIGHTS RESERVED
8’–24’ POWERFOIL
®
X2.0 WASHDOWN & POWERFOIL
®
X2.0PLUS WASHDOWN
4a. Fasten single angle irons to roof structure
Fasten the angle irons to the roof structure mounting points at each end with customer-supplied hardware as shown.
Do not tighten the
hardware until the upper yoke has been mounted to the angle irons (step 5).
Big Ass Fans recommends orienting the angle irons so
that the horizontal legs are facing each other (vertical legs are on the outside).
Proceed to step 5.
Grade 8 Hardware (Customer-Supplied):
a. (4) 1/2-13 Bolt
b. (8) 1/2” Washer
c.
(4) 3” Square Washer (BAF-Supplied; see diagram)
d. (4) 1/2” Nylock Nut
Mounting Structure: Bar Joists (cont.)
b
a
c
b
d
Vertical walls are
to the outside.
Note: Ensure the angle irons are oriented as shown.
Square Washer
Thickness:
1/4” (6 mm)
3”
(7.6 cm)
3”
(7.6 cm)
Ø 9/16”
(1.4 cm)
If the angle iron span is greater than 8 ft (2.4 m) and requires double angle irons, proceed to step 4b.
Summary of Contents for powerfoil x2.0
Page 6: ......
Page 48: ......
Page 56: ...Notes...
Page 58: ......
Page 66: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ...002972 002972 2425 Merchant St Lexington KY 40511 1 877 BIG FANS WWW BIGASSFANS COM REV J...