PIVOT™ 180
31
WWW.BIGASSFANS.COM ©2011 DELTA T CORP. ALL RIGHTS RESERVED
PIVOT™ 180
Electrical Installation (cont.)
Wiring: 200–250V three-phase fan controllers
WARNING: Wait three minutes after disconnecting before servicing!
WARNING: Improper installation can cause electric shock or damage to the motor and controller. A qualified electrician
should perform the installation.
The diagram below shows wiring options for a 200–250V 3Φ fan controller. See “Power Requirements for Fan Controllers” on page 25
for detailed power requirements.
U
/T1
V
/T2
W
/T3
PE
L1
L2 L3
1 2 5 6
13A13B13C 14 30 16 17
25 4 11
1 2 5 6
13A13B13C 14 30 16 17
25 4 11
L1
L2
L3
U
/T1
V
/T2
W
/T3
PE
L1
L2 L3
1 2 5 6
13A13B13C 14 30 16 17
25 4 11
1 2 5 6
13A13B13C 14 30 16 17
25 4 11
L1
L2
L3
RED
BLA
CK
BL
UE
BR
OWN
BLA
CK
BLA
CK
RED
BL
UE
RED
BLA
CK
BL
UE
BR
OWN
BLA
CK
BLA
CK
RED
G
RE
EN
W
/ Y
EL T
RAC
KER
GR
EEN
W/ Y
EL TRACKER
GR
EEN
W/ Y
EL TRACKER
G
RE
EN
W
/ YE
L TR
ACKE
R
Wiring for 200–250V 3Φ, 50/60Hz fan controllers
A disconnect is included with the fan controller for
200–250V 3Φ. An EMI filter is not included with this
fan controller.
Note: This fan controller does not contain fusing!
Power must be supplied to this controller via
a dedicated circuit breaker or properly fused
disconnect!
Optional 1Φ wiring for 200–250V 3Φ, 50/60Hz controllers
The L3 terminal is not used when wiring the fan
controller for 200–250V 1Φ. A disconnect is included
with the fan controller. An EMI filter is not included with
this fan controller.
Note: This fan controller does not contain fusing!
Power must be supplied to this controller via a
dedicated circuit breaker or properly fused disconnect!
AC Input Wiring
3W plus GND
Motor Output Wiring
3W plus GND
AC Input Wiring
2W plus GND
Motor Output Wiring
3W plus GND