BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Tel.: 02196 720480
Fax.: 02196 7204820
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed
RECOMMENDED COMPRESSED AIR SYSTEM
No.
Designation
No.
Designation
1 Air tool
6 Drainage/filtering unit
2 Air hose
7 Drainage valve
3 Quick coupling
8 Shut-off valve
4
Oiler
(for tools with motor)
9 Dryer/filter unit
5 Pressure reducer
10 Compressor
MAINTENANCE
•
Air tools should be operated on air systems that have an automatic oiler.
When using air systems that do not have an automatic oiler, air tools
must be regularly added oil to the air tool via the air connection.
•
Before first use, add 4 to 5 drops of air device oil to the air connection of
the device.
•
Do not use engine or gear oil, to oil pneumatic tools; only use oil for
pneumatic tools.
•
Drain the compressed air system before each use. Water in the air lines
leads to a loss of performance and damage to the air tool.
•
Clean or replace the air filter on the compressor at the prescribed
intervals.
•
Only operate the air tool with the maximum pressure specified in the
chapter "Technical data".
COMPONENTS
1
Cutting disc
2
Safety cover
3
Trigger lever
4
Safety lever
5
Adjusting ring
6
Cap / Air inlet