BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Tel.: 02196 720480
Fax.: 02196 7204820
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed
INTENDED USE
The compression tester is a valuable tool for the diagnosis of engines, which can be both age-related
and tear as well as leakage of the piston rings and valves notice. Through the adaptation of the
compression tester has a wide range of application such as. e.g. diagnosis of cars, motorcycles and
other machines with 2- or 4-stroke engines.
SAFETY INFORMATIONS
Read the following safety instructions carefully before using the product. Failure to observe the safety
instructions can result in damage, injuries and void the warranty.
Take care when checking hot engines, there is a risk of burns on the hot exhaust manifold or
other hot engine parts!
Be careful with running engines, loose or baggy clothing can be caught in rotating parts and
cause injuries.
Only work in a well-ventilated area. Do not inhale exhaust gases and fuel vapors.
Always be careful when working on fuel systems. The fuel in the fuel line may be pressurized
even when the engine is not running.
These operating instructions provide general tool information. Always refer to the vehicle-
specific service literature, this contains data, repair instructions and special warnings.
Before starting repairs, secure the vehicle against accidental starting. (Remove ignition key or
disconnect battery)
Keep children and other unauthorized persons away from the work area.
Do not let children play with the tool or its packaging.
Always keep a fire extinguisher nearby. This must be suitable for fuel-related, electrical or
chemical fires.
Do not smoke during repairs. Smoking and open flames can lead to fire.
Always keep tools in the case and in a safe, dry place out of the reach of children.
Disconnect the supply voltage to the ignition coils and the petrol injection nozzles.
Disconnecting the high voltage ignition cables alone can damage the ignition system, cause
fire and electric shock.
PRESSURE GAUGE
8
9
10
11
12
13
14
Display shows value in selected unit
Button
LED/ZERO
: Switched backlight on or off / Set value to zero
Button MEM/CLR: Value memorizing / Delete memory
Button
Unit/PWR
: Switch on gauge / Select measuring unit
Pressure release valve
Quick coupler release ring
Quick coupler
SHORT DESCRIPTION OF FUNCTION KEYS
LED / ZERO
Button (9)
Press short; Switched On / Off the backlight.
Press longer than 2 sec.; Delete the memory and set the gauge to 0
MEM / CLR
Button (10)
Press short; Save value and change memory index
Press longer than 2 sec.; Delete the memory
Unit / PWR
Button (11)
Press short; Select the measuring unit
Press longer than 2 sec.; Switched gauge on