Maintenance
Manual No. 107013
Maintenance
5-33
January 1, 2018
Operating Instructions and Parts List for the Quantum Flex
™
Trimmer
FAULT DETECTION AND CORRECTION
.
PROBLEM
PROBABLE CAUSE
REMEDY
Handpiece Vibration
Inside bore of handpiece
frame worn out.
Replace frame.
Worn handpiece bearing.
Replace.
Worn pinion gear.
Replace.
Worn teeth on blade or
pinion gear.
Replace.
Blade too loose in blade
housing.
Adjust blade housing. If still too
loose, try a new blade in the
housing.
Blade too tight in the
housing.
Adjust blade housing.
Whizard Quantum
®
Driveline or Whizard
®
Flexshaft is worn.
Replace.
Handpiece Hot
Pinion gear tight in hand-
piece bearing.
Clean corrosion from the hand-
piece bearing and lubricate.
Blade tight in blade
housing.
Adjust blade housing.
Handpiece bearing not
installed correctly - (No
clearance between face
of pinion gear and blade
housing) causing
mechanical bind.
Reinstall bearing correctly. With
handpiece removed from
Whizard Quantum
®
Driveline,
you should be able to rotate the
blade freely by hand.
Rapid Wear
or breakage of the
driveline or flexshaft.
Mechanical bind in hand-
piece.
With handpiece removed from
driveline, blade should rotate
freely by hand. Correct any
mechanical bind.
Drive unit not installed at
proper height or location.
Install drive unit per instructions
in drive unit manual.