Unpacking and Installation
3-10
Unpacking and Installation
Manual No. 107013
Operating Instructions and Parts List for the Quantum Flex
™
Trimmer
January 1, 2018
ATTACHING QUANTUM FLEX
™
TRIMMER TO THE WHIZARD
QUANTUM
®
DRIVELINE OR WHIZARD
®
FLEXSHAFT AND CASING
ASSEMBLY
The Disconnect Casing
•
Hold the trimmer in the hand you will use in operation, and with the other hand, grasp the
Whizard Quantum
®
driveline or Whizard
®
flexshaft and casing assembly and push it into
the end of the tool through the handle retaining knob until the latch catches the detent.
•
The disconnect lever rotates freely around the handle.
•
Align the disconnect lever in the notched-out area of the handle. Slightly open the fingers on
the hand holding the trimmer. Push the driveline or flexshaft casing assembly inward and
hold the lever down in the handle groove with the normal operating hand.
•
Check to see that the lever is seated completely flat within the groove.
•
Release the lever and the casing should pop out and stop the blade from turning. The motor
will continue to operate.
DISCONNECT LEVER