16
To Remove Needle(s)
–
Turn the hand wheel counterclockwise until the
needles are at their highest position.
–
Hold the needle to be removed with the needle
holder (stored in the looper cover).
–
Loosen the setscrew and remove the needle.
(A)
Left needle (LN)
(B)
Right needle (RN)
(C)
Left Coverstitch Needle (LC)
(D)
Center Coverstitch Needle (CC)
(E)
Right Coverstitch Needle (RC)
To Insert Needle(s)
–
Hold the needle with the flat surface
(1)
to the
back.
–
Insert the needle into the needle socket as far
as it will go.
–
When inserting a needle, if you first lower it
down into the hole in the stitch plate it will line
up with the needle socket. Then direct it
upwards.
This machine uses ELx705 needles.
Do not use Standard Household Needles.
1
2
3
A
A B
B
B
C
C
D
D
E
E
A
B
C
D
E
A
B
C
D
E
D
1
2
3
A
A B
B
B
C
C
D
D
E
E
A
B
C
D
E
A
B
C
D
E
D
PLEASE NOTE:
When inserting needles into the
(A,B)
or
(C, D,
E)
sockets it is necessary to loosen
(3)
all Allen
Screws.
After inserting the needles equally tighten all
Screws
(2)
.
CAUTION:
Be sure to disconnect the machine from the