Command START
End position Door Open
Closing¹
Reset hold open time to the beginning
End position Door Closed
Opening¹
Opening
Opening (>Door Open)
Stop
None (opening is continued)
Opening (>Ventilation)
Stop
Stop
Closing
Stop
Stop - Opening – Hold open time...
End position Ventilation
Opening¹
Opening¹
Command VENTILATION
End position Door Open
Closing¹ to the ventilation position
Reset hold open time to the beginning
End position Door Closed
Opening¹ to the ventilation position
Opening¹ to the ventilation position
Opening (>Door Open)
None (opening is continued)
None (opening is continued)
Opening (>Ventilation)
Stop (and after the renewed operating command Closing)
Closing
Stop
Stop - Opening – Hold open time...
End position Ventilation
Closing¹
Closing¹
Triggering safety elements
End position Door Open
None (START is ignored)
None (START/automatic closing was ignored)
(to terminals L...)
End position Door Closed
None (START is ignored)
None (START/automatic closing was ignored)
Opening
None (opening is continued)
None (opening is continued)
Closing
Stop – reversing
Stop – reversing after Door Open
End position Ventilation
None (START is ignored)
None (START/automatic closing was ignored)
Triggering safety elements
End position Door Open
None (START was ignored)
None (START/automatic closing was ignored)
(to terminals NOT)
End position Door Closed
None (START was ignored)
None (START/automatic closing was ignored)
Opening
None (opening is continued)
None (opening is continued)
Closing
Stop – reversing
Stop – reversing after Door Open
End position Ventilation
None (START was ignored)
None (START/automatic closing was ignored)
Obstacle/force cut-off
Opening
Stop
Stop
Closing
Stop – reversing
Stop – reversing after Door Open
Power supply re-established
End position Door Open
None
None
(after a power failure...)
End position Door Closed
None
None – automatic closing is NOT continued!
Opening Stop
Stop
Closing Stop
Stop
End position Ventilation
None
None – automatic closing is NOT continued!
Event...
...during the door status²...
...leads in operating mode
...leads in operating mode
Pulse repetition to:
Automatic closing to:
9.4 OPERATING CONDITIONS
¹ possibly after a set prewarning time
² various door stati, explicitly „during the prewarning time“, are
not recorded here; the control unit generally returns here into
a safe status in order to avoid any unexpected functions if an
operating command was either triggered unintentionally or
also by a second user.
An example:
In the operating mode automatic closing and the end position
Door Open the hold open time has expired, the prewarning time
of the caution light is running: an operating command ventilati-
on or Start leads to a reset of the hold open time, which means:
the preset hold open time begins to run again.
Summary of Contents for G 501
Page 1: ...1 USER MANUAL WWW BERNAL DE BERNAL GERMANY 8 8 GB G 501...
Page 2: ...2 GB Your comfort is our drive...
Page 50: ...50 GB OVERVIEW OF THE STRUCTURE OF THE MAIN MENU LEVEL 1 04...
Page 51: ...51 GB SETUP SETTING FORCE DISTANCE TRAVEL PATH AND FORCE CURVE MENU P SEE 5 1 ff 05...
Page 52: ...52 GB SETUP TRANSMITTERS PROGRAMMING A HAND TRANSMITTER MENU C 1 SEE 6 1 06...
Page 53: ...53 GB SETUP TRANSMITTERS DELETE A HAND TRANSMITTER MENU C 2 SEE 6 2 07...
Page 54: ...54 GB SETUP TRANSMITTER DELETE ALL TRANSMITTERS MENU C 2 SEE 6 2 08...
Page 57: ...57 GB SPECIAL FUNCTIONS FUNCTION VENTILATION MENU S 1 TO S 3 SEE 7 5 1 11...
Page 59: ...59 GB 13 DRIVE PARAMETERS MENU b SEE 8 ff...
Page 60: ...60 GB 16...