2.2.1 - 2.3.1 – 2.3.2 – 2.3.5 – 2.3.6
5.1 PREREQUISITES
The set up must take place inside the garage in order to have
access to the drive if a fault occurs.
Assembly must be fully completed and the manual function
test (3.2.8) must be performed successfully.
The carriage must be locked in the drive dog.
Only for the version of the device without a display: acceptance
testing of the drive hood is essential for performing the set-up
(Figure 34) – the covers on the 230 V/AC area of the control
board (see Figure 40) should never be removed!
5.2 SET UP OF THE GARAGE DOOR DRIVE
The attached safety equipment is NOT EFFECTIVE du-
ring set up!
The automatic obstacle detection / force cut-off is NOT
EFFECTIVE during set up!
Perform the set up on the basis of the programming ma-
nual after you have informed yourself about the general
processing sequence from the following information.
If the set up is opened then the points „5.4 Programme paths“
and „5.5 Programme the force curve“ must be executed one af-
ter the other and must be fully completed. Breaking off during
set up leads to a restart of set up! This set up setting can only
be interrupted by pulling out the power plug. The integral drive
light is deactivated during set up.
Set up for first commissioning or after “Reset parameters” to
the factory settings:
Create a power supply by plugging in the power plug; the gara-
ge door drive executes a self test for about 5 seconds.
For the version of the device without a display the set-up assis-
tant starts the menu autonomously with menu point „P“ (Set-
ting force / distance).
For the version of the device with a display (G 501) the request
is made to select the language. Then the set up assistant starts
the menu autonomously with menu point „P“ (Setting force /
distance).
Set-up for repeating (after changes have been made to the ma
chine–travel paths and force curves are already programmed
in).
Activate programming and enter menu P.
5. INITIALISATION (SET UP) (MENU P)
5.3 DOOR TYPE
Only for use of the drive on swing doors which open outwards
(Figure 3, e), the type of drive must be setup (the direction of
rotation of the drive is in the opposite direction here): Activate
door type „swing door“ before set up is begun with „run UP“. An
additional adaptation of difficult movement cycles or force cyc-
les is possible after set up via Soft start / stop (see 8.2).
5.4 PROGRAMME RUNWAYS
Set up started with „Run UP“: Control the door through repea-
ted pressing of the button into the end position „Door Open“.
Do not move into the mechanical limit of the door mechanism
in the process! Resetting can be achieved using „Run DOWN“
if necessary. Store the desired position „Door Open“. Set up
changes over to „Run DOWN“:
Control the door through repeated pressing of the button into
the end position „Door Closed“. Do not move into the mecha-
nical limit of the door mechanism in full operation! Resetting
can be achieved using „Run UP“ if necessary. Store the desired
position „Door Up“. The set-up assistant changes to „Program-
ming run force“:
5.5 PROGRAMME FORCE CURVE
Start the Programming movement for force by pressing once via
„Start programming run“. The door performs a full cycle „Open-
Stop-Close-Stop“. The individual force values for the previously
read-in pathway points are measured out during this cycle and
saved as an individual force curve.
The set-up is ended automatically after successful program-
ming of the force. The drive switches over into operational rea-
diness.
After set up check the the obstacle detection / force cut-
off (see 12.2). Programme further hand transmitters or
accessories if necessary and / or programme the gara-
ge door drive correctly.
To finalise the commissioning provide / perform che-
cking, product documentation, the conformity declara-
tion, operator / user briefing.
Summary of Contents for G 501
Page 1: ...1 USER MANUAL WWW BERNAL DE BERNAL GERMANY 8 8 GB G 501...
Page 2: ...2 GB Your comfort is our drive...
Page 50: ...50 GB OVERVIEW OF THE STRUCTURE OF THE MAIN MENU LEVEL 1 04...
Page 51: ...51 GB SETUP SETTING FORCE DISTANCE TRAVEL PATH AND FORCE CURVE MENU P SEE 5 1 ff 05...
Page 52: ...52 GB SETUP TRANSMITTERS PROGRAMMING A HAND TRANSMITTER MENU C 1 SEE 6 1 06...
Page 53: ...53 GB SETUP TRANSMITTERS DELETE A HAND TRANSMITTER MENU C 2 SEE 6 2 07...
Page 54: ...54 GB SETUP TRANSMITTER DELETE ALL TRANSMITTERS MENU C 2 SEE 6 2 08...
Page 57: ...57 GB SPECIAL FUNCTIONS FUNCTION VENTILATION MENU S 1 TO S 3 SEE 7 5 1 11...
Page 59: ...59 GB 13 DRIVE PARAMETERS MENU b SEE 8 ff...
Page 60: ...60 GB 16...