Installing the device
35
Attaching the device
DANGER
Fatal electric shock due to a live cable
on the wall
¾
Switch off the voltage supply of the
pre-assembled connection cable.
¾
Make sure that the pre-assembled
connection cable contains no
voltage.
¾
Make sure that the connection cable
is not damaged during installation.
¾
Only have work on the voltage
supply carried out by a qualified,
trained specialist electrician under
consideration of the country-specific
regulations and standards (in
Germany e.g.
DIN 57100/VDE 0100, Part 701).
WARNING
Danger due to falling parts in the event
of improper mounting.
¾
The enclosed mounting material is
exclusively suitable for mounting on
a solid wall construction.
¾
Make sure that the wall has sufficient
carrying capacity and use suitable
mounting material.
¾
Make sure that the device is
mounted correctly.
Before hooking the device in, the connection cable
for the voltage supply must be prepared for
function, i.e. it must be routed in the correct
position, fitted with a Wieland connector and
connected. The connection cable must not contain
any voltage.
¾
Guide the connection cable through the cable
passage opening and into the device from the
rear side.
¾
Lift the device onto the installation rails with two
persons.
¾
Make sure that both mountings are seated