Installing the device
34
Drilling the required holes
DANGER
Fatal electrical shock due to drilling
into an electrical cable.
¾
Never drill into electrical cables
routed in the wall. Use a metal
detector before drilling.
¾
Make sure that no electrical cables
are present in the wall at the marked
points.
DANGER
Risk of explosion due to gas pipes
routed in the wall.
¾
Use a detector to make sure that no
gas pipes are present in the wall at
the marked points.
ATTENTION
Water damage due to drilling into a
water pipe.
¾
Use a detector to make sure that no
water pipes are present in the wall at
the marked points.
ATTENTION
Damage to the surface of tiles due to
drilling.
¾
Use a masonry drill bit for pre-drilling
when drilling into tiles.
¾
Switch off the hammer function and
drill carefully.
A hammer drill and a masonry drill bit d = 8 mm are
required for this step.
¾
Drill the holes required for the fastening points
(1.).
¾
Insert the enclosed plugs (2.).
Securing the installation rails
¾
Secure each of the installation rails with two of the
enclosed screws.