Preparing for installation
30
Pre-assembling the electrical
connection cable (air extraction and
recirculated air device)
DANGER
Fatal electric shock due to improperly
carried out electrical work.
¾
Only have work on the voltage
supply carried out by a qualified
specialist electrician under
consideration of the country-specific
regulations and standards (in
Germany e.g.
DIN 57100/VDE 0100, Part 701).
A permissible, approx. 0.5 m-long connection cable
is required for connecting the device to the
domestic mains.
The Wieland connector is not accessible following
installation. An all-pole isolating device (contact
opening greater than 3 mm) must be available.
¾
Only install the connection cable within the
prescribed position range.
¾
For the position (1) of the recirculated air device,
refer to the connection dimension drawing on
page 10.
¾
For the position (1) of the air extraction device,
refer to the connection dimension drawing on
page 13.
The following steps must only be carried out by a
specialist electrician:
¾
Make sure that the mains voltage corresponds to
the voltage specified on the extractor hood's
model plate.
¾
Shorten the connection cable to a length of 0.5 m.
During transportation, the Wieland socket is
connected to the Wieland connector in the extractor
hood.
¾
Remove the Wieland socket from the device.
¾
Connect the Wieland socket to the 0.5 m long
connection cable.
The connection cable is pre-assembled.