48
KYO320
EVENT
CONTACT ID
SIA
CL. CODE GROUP
ZONE
TYPE
1
st
2
nd
Warning low battery on Power station
3
02
00
000
YT/YR
0000
000
Warning power trouble on Power station
3
03
00
000
YM/YR
0000
000
Battery not connected on Power station
3
00
00
000
YP/YQ
0000
000
Battery charger trouble on Power station
3
00
00
000
YP/YQ
0000
000
Switching not connected on Power station
3
00
00
000
YP/YQ
0000
000
Short circuit output ½/3 on Power station
3
00
00
000
YP/YQ
0000
000
Battery low memory
3
07
00
000
YT/YR
0000
000
Warning low battery on wireless device
3
38
00
000
XT/XR
0000
000
Memory tamper BPI device
3
41
00
000
ET/ER
0000
000
Memory balanced tamper
1
37
00
000
TA/TR
0000
000
Memory tamper on main unit
1
37
00
000
TA/TR
0000
000
Memory false key
4
21
00
000
DD/DR
0000
000
Memory tamper supervised output
3
21
00
000
YA/YR
0000
000
Lost wireless zone
3
33
00
000
ET/ER
0000
000
Warning generic
3
00
00
000
BT/BJ
0000
000
Installer maintenance
6
00
00
000
QA/QH
0000
000
Central station maintenance
6
00
00
000
QA/QH
0000
000
Standard time/Summer time changed
6
25
00
000
JD/UX
0000
000
Not Ready-to-arm partition
3
00
part. no.
000
NF/NF
part. no.
000
Extended not Ready-to-Arm partition
3
00
part. no.
000
NF/NF
part. no.
000
Partial arming partition
4
41
part. no.
5
NL/OP
part. no.
000
Global arming partition
4
00
part. no.
5
CL/OP
part. no.
000
Disarming partition
4
00
part. no.
5
OP/CL
part. no.
000
Exit time on partition
6
00
part. no.
000
UX/UX
part. no.
000
Entry time on partition
6
00
part. no.
000
UX/UX
part. no.
000
Autoarming warning partition
6
00
part. no.
000
UX/UX
part. no.
000
Memory alarm on partition
1
30
part. no.
000
BA/BR
part. no.
000
Memory tamper on partition
1
37
part. no.
000
TA/TR
part. no.
000
Valid key
4
22
00
key no.
JP/UX
0000
key no.
Key present on reader
4
22
00
reader no.
JP/UX
0000
reader no.
Valid key on partition
4
22
00
partition no.
JP/UX
0000
partition no.
Alarm stop on partition
6
00
part. no.
000
BC/UX
part. no.
000
Alarm stop on panel
6
00
00
000
BC/UX
0000
000
Bypass zone
5
70
00
zone no.
BB/BU
0000
zone no.
Telephone line trouble
3
51
00
000
LT/LR
0000
000
Error printer
3
36
00
000
VT/VR
0000
000
Call queue full
6
24
00
000
JL/UX
0000
000
Timer
6
00
00
000
UX/UX
0000
000
Tab le 12
Struc tu re of the main Re porting for mats sup ported by the Sys tem (con tin ued ...)
5
Tran smits the Iden ti fi ca tion Num ber, re du ced by 1 unit, of the User Code which pro du ced the event (from 000 to
194) or the Iden ti fi ca tion Num ber, in cre a sed by 199 units, of the Di gi tal Key which pro du ced the event (from 200 to
699). For exam ple, if the event was pro du ced by User Code no.1, 000 (1-1) is tran smit ted; if the event was pro du ced
by Di gi tal Key no.1, 200 (1 + 199) is transmitted.