For Alarm zo nes — the Par ti tion pa ra me ter de ter mi nes
the par ti tions the zone be longs to, and thus its ope ra ting
ti mes, co des and keys.
For
Com mand
zo nes — the
Par ti tion
pa ra me ter de ter mi -
nes the par ti tions the com mand will af fect. Each Com -
mand zone can af fect more than one Par ti tion.
To se
lect/de se lect par
ti tions
1 thro
ugh 8, press the
cor re spon ding key: “
û
”
me ans the zone be longs to the
cor re spon ding par ti tion.
To go to the next gro up of par ti tions
, press
B
.
For par ti tions 9 thro ugh 16 — key
1
cor re sponds to par -
ti tion 9, key
2
to par ti tion 10 and so forth to key
8
which
cor re sponds to par ti tion 16. The same re a so ning ap -
plies to par ti tions 17 thro ugh 24 and par ti tions 25 thro -
ugh 32.
11.
Press
ENTER
.
Options
Enable autoarm -
12.
Using
A
or
B
, se lect the
Ena ble au to arm
op tion (re -
fer to “Auto-arm on de lay”) or
Full ar ming Al.
(re fer to
“Full Arming Alarm”).
Using
ON
or
OFF
, re spec ti vely, ena ble or di sa ble the
op tion con cer ned, then press
ENTER
to con firm and
con ti nue.
Timeout
Di
sa
bled
13.
If the
Ena ble au to arm
op tion is
OFF
, go di rectly to
the next step.
If the
Ena ble au to arm
op tion is
ON
, en ter the re qui red
Ti me o ut
(re
fer to “
Inac ti vity Time
”), then press
ENTER
to con firm and con ti nue.
Inactivity Time
Disabled
13.
If the
Ena ble au to arm
op tion is
OFF
, go di rectly to
the next step.
If the
Ena ble au to arm
op tion is
ON
, en ter the re qui red
Ti me o ut
(re
fer to “
Inac ti vity Time
”), then press
ENTER
to con firm and con ti nue.
14.
Enter the re qui red
Inac ti vity
time
(re fer to “Inac ti -
vity”) or, using
0
, se lect
Di sa bled
to stop Inac ti vity su -
per vi sion. Press
ENTER
to con firm and go to the next
step.
Low threshold
Volts 34%
This Con
trol pa
nel can si
gnal zone Alarm, Tam
per,
Short-cir cu it and Standby. To pro vi de the va rio us si -
gnals, the Con trol pa nel must me a su re the vol ta ge on
the zone ter mi nals and com pa re it with the
Thre shold
va lu es pro gram med in this sec tion.
The Thre sholds must be set bet we en 00 % and 99 %. The
Thre sholds must be pro gram med with ri sing va lu es.
15.
Using
A
or
B
, se lect the re qui red Thre shold:
Low
,
Mid
,
High
, en ter the va lue (e.g. For 5 % en ter 05), then
press
ENTER
.
Wi re less Zones
This system sup ports up to 32 wi re less zo nes.
To pro gram the wi re less zo nes, using the
ESC
key, go
to step 3 in the “Zo nes” sec tion.
Zones
Wi
re
less Zones
(281 Zo nes for Kyo320)
3b.
Using
A
or
B
, se lect the
Sel. wls zone
op tion then press
ENTER
.
Wls zone n. 001
Zone 281
4b.
Using
A
or
B
, se lect the wi re less zone to be pro -
gram med, then press
ENTER
.
De
scri
ption
Zone 281
5b.
Enter the zone la bel (re fer to “Edi ting a text” un der
“Using the Key pad”), then press
ENTER
.
Zone 281
Su
per
vi
sio
n x
If the Su per vi sion op tion is ena bled, the system will be
able to de tect zone tro u ble (e.g. de tec tor tro u ble). Each
wi re less de vi ce will send a su per vi sory si gnal to the Re -
ce i ver at re gu lar in ter vals. If the Re ce i ver does not re ce -
i ve the si gnal wit hin the su per vi sory win dow (re fer to
“Vec tor-RX mo du le”), it will ge ne ra te a su per vi sory fa ult
(
Lost wi re less zone
event).
Use
ON
or
OFF
, re spec ti vely, to ena ble or di sa ble the
Su per vi sion at tri bu te, then press
ENTER
.
Zone type
Instan
t x
Using
A
or
B
, se lect the zone type:
Instant
,
Entry de -
lay
,
Entry path
,
Exit de lay
,
Last exit
,
24 ho urs
and
Fire
.
To ena ble/di sa ble the zone type, use
ON
or
OFF
:
“
û
” me ans ena bled and “
-
” di sa bled.
6b.
Press
ENTER
.
Zone attribute
Unbypassable
Se tup the zone at tri bu tes:
Unbypas sa ble
,
Test
,
Au -
tob ypas sa ble
,
Au tobyp.+re inc.
(re fer to “Au tob ypass
with re set unbypass”),
Stay
,
De lay on part.
(re fer to
“De la yed on stay ar ming”),
Del&Est. r.t.a.
(re fer to “De -
la yed and esti ma ted on re ady to arm”).
Using
A
or
B
, se lect the at tri bu te. Press
ON
or
OFF
, re -
KYO320
PROGRAM PANEL
23