2.
Fix the Mo du le to the base of the con trol unit using
the screws sup plied, ma king sure it is cor rectly ali -
gned with the screw an chor ho les (
144
).
3.
Con nect the Mo du le con nec tor (
130
) to the con trol
unit se rial port (
143
) using the PC-Link ca ble sup -
plied (
140
).
4.
Con nect con
nec tor (
132
) to the LAN using an
Ether net ca ble.
+
Use a ca te gory 5 (or bet ter) shiel ded Ether net ca -
ble (STP or FTP).
5.
Whe re pre sent, con nect the [OC] ter mi nal to ter mi -
nal block (
134
).
6.
Con nect ter
mi nals [+V] and [M] on the ter
mi nal
block (
134
) to the cor re spon ding ter mi nals [+B4]
and [M] on the con trol unit mot her bo ard (
142
).
7.
Re con nect the con trol unit to the po wer supply.
8.
Pro gram the K-NET Mo
du le as de scri bed in the
"Pro gram ming" sec tion of the K-NET ma nual.
n
Technical Specifications
The fol lo wing ta ble con ta ins the tec hni cal spe ci fi ca tions
of the K-NET Mo du le.
Voltage
9.6 ÷ 27.6 V
_
Current draw
250 mA
Standby current
50 mA
Operating Temperature
-5 ÷ +40 ° C
Dimensions (W x H x D)
95 x 65 mm
Reset default
To re
set the fac
tory de
fa ult pro
gram ming (see the
Instal la tion Ma nual Vol.1) :
1.
Re mo ve all po wer from the Con trol pa nel (Ma ins
and bat tery).
2.
Re mo ve the jum per
21
(M).
3.
Wait at le ast 20 se conds.
4.
Re pla ce the jum per
21
(M).
5.
Re set the po wer supply to the Con trol Pa nel (see
“Con nec ting a Po
wer Supply” in the
“INSTALLATION” chap
ter in the Instal
la tion Ma
-
nual, Vol.1).
!
Jum per 21 (M) must be di scon nec ted for at le -
ast 20 se conds in or der to en su re full re set of
the fac tory de fa ult pro gram ming, and to avo id
pro blems that may oc
cur when the po
wer
supply is re sto red.
Installer code locked
If the
Lock Instal ler code
op -
tion is ena bled, the Instal ler PIN will not be able to re set
to fac tory de fa ult (re fer to Lock Instal ler code in the
Options sec tion in the Instal la tion Ma nual Vol.1).
Reporting Formats
This pa ra graph de scri bes the struc tu res of the main re -
por ting for mats sup por ted by the system.
n
TELIM
The TELIM pro to col tran smits as fol lows:
Ø
User Code
(4 di gits — 0 thro ugh 9);
Ø
Event Code
:
41
in the event of Alarm or Tam per on the
first 16 zo nes of the Con trol pa nel,
0
in all ot her ca ses;
Ø
2 byte (16 bit) re pre sen ting the sta tus of the first 16
zo nes —
0
Standby;
1
= Alarm or Tam per.
n
Contact ID
Con tact ID tran smits as fol lows:
Ø
User Code
(4 he xa de ci mal di gits — 0 thro ugh F );
Ø
Qua li fier: 1
= new event or Di sar ming ope ra tion;
3
event re sto re event or Arming ope ra tion
Ø
Class Code
(
CL.
co lumn): iden
ti fies the type of
event (Alarm, Tro u ble, Fire, etc.);
Ø
Event Code
(
CODE
co lumn): iden
ti fies the event
(Event Co des can be chan ged, re fer to “Actions” un -
der “Di gi tal Com mu ni ca tor” in the “PROGRAMMING”
sec tion in the Instal la tion Ma nual Vol.1);
Ø
Gro up Num ber
(
GROUP
co lumn), whe re pos si ble,
iden ti fies the Par ti tion of the “ob ject” which ge ne ra -
ted the event;
Ø
Zone Num
ber
(
ZONE
co
lumn), whe
re pos
si ble,
iden ti fies the “ob ject” (Zone, Code, Key, etc.) which
ge ne ra ted the event.
n
SIA/SIA over B-NET
SIA/SIA over B-NET is a FSK (Fre quency Shift Ke ying)
for mat, that tran smits al ter na ti vely in two slightly dif fe rent
46
KYO320
EVENT
CONTACT ID
SIA
CL. CODE GROUP
ZONE
TYPE
1
st
2
nd
Alarm on zone
1
30
00
zone no.
BA/BR
0000
zone no.
Tamper on zone
1
37
00
zone no.
TA/TR
0000
zone no.
Fire alarm on partition
1
10
part. no.
000
FA/FR
part. no.
000
24h alarm on partition
1
33
part. no.
000
BA/BR
part. no.
000
Tab le 12